Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
148
matching recommendationsSIC | 327 | Concrete, Gypsum, And Plaster Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0257 # 03 Y:1999 | 03 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,802 | $2,140 | Implemented |
AS0257 # 04 Y:1999 | 04 | 1999 | USE SYNTHETIC LUBRICANT | $148 | $360 | Not Implemented |
AS0257 # 05 Y:1999 | 05 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $728 | $60 | Not Implemented |
AS0257 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $203,979 | $64,000 | Implemented |
AS0257 # 07 Y:1999 | 07 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $149 | $15 | Not Implemented |
AS0239 # 01 Y:1998 | 01 | 1998 | USE SYNTHETIC LUBRICANT | $1,810 | $1,710 | Not Implemented |
AS0239 # 02 Y:1998 | 02 | 1998 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,088 | $3,600 | Not Implemented |
AS0239 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,473 | $23,248 | Not Implemented |
AS0239 # 04 Y:1998 | 04 | 1998 | USE OPTIMUM THICKNESS INSULATION | $11,065 | $3,346 | Not Implemented |
AS0239 # 05 Y:1998 | 05 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $141,705 | $103,000 | Not Implemented |
AS0239 # 06 Y:1998 | 06 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $7,760 | $120 | Not Implemented |
AS0239 # 07 Y:1998 | 07 | 1998 | MINIMIZE WATER USAGE | $18,668 | $82,192 | Not Implemented |
AS0239 # 08 Y:1998 | 08 | 1998 | ADOPT IN-HOUSE MATERIAL GENERATION | $72,397 | $325,070 | Not Implemented |
AS0225 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,749 | $5,531 | Not Implemented |
AS0225 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $508 | $1,200 | Not Implemented |
AS0225 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $600 | $825 | Implemented |
AS0225 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,028 | $4,538 | Implemented |
AS0225 # 05 Y:1998 | 05 | 1998 | USE SYNTHETIC LUBRICANT | $1,949 | $4,010 | Not Implemented |
AS0225 # 06 Y:1998 | 06 | 1998 | METER WASTE WATER | $14,160 | $5,000 | Not Implemented |
AS0225 # 07 Y:1998 | 07 | 1998 | REDUCE OR ELIMINATE WASTE | $8,725 | $1,000 | Not Implemented |
AS0225 # 08 Y:1998 | 08 | 1998 | ADD ADDITIONAL PRODUCTION SHIFT | $75,180 | $240 | Implemented |
AS0191 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,786 | $2,100 | Not Implemented |
AS0191 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $457 | $960 | Not Implemented |
AS0191 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,267 | $0 | Implemented |
AS0191 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,678 | $420 | Implemented |