Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 329 | Misc. Nonmetallic Mineral Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0869 # 05 Y:2012 | 05 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $4,610 | $8,000 | Not Implemented |
UD0869 # 08 Y:2012 | 08 | 2012 | COVER OPEN TANKS | $1,504 | $1,000 | Not Implemented |
UD0869 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $753 | $825 | Implemented |
UD0869 # 02 Y:2012 | 02 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,891 | $0 | Implemented |
UD0869 # 03 Y:2012 | 03 | 2012 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $4,665 | $2,000 | Not Implemented |
UD0869 # 04 Y:2012 | 04 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,400 | $57,000 | Not Implemented |
UD0869 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,808 | $1,000 | Implemented |
UD0869 # 07 Y:2012 | 07 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,105 | $400 | Not Implemented |
UD0869 # 09 Y:2012 | 09 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $64,740 | $51,900 | Not Implemented |
MA0700 # 07 Y:2012 | 07 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $913 | $500 | Implemented |
MA0700 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,148 | $500 | Implemented |
MA0700 # 05 Y:2012 | 05 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,934 | $500 | Implemented |
MA0700 # 04 Y:2012 | 04 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,265 | $500 | Implemented |
MA0700 # 01 Y:2012 | 01 | 2012 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $16,572 | $12,830 | Not Implemented |
MA0700 # 02 Y:2012 | 02 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,586 | $24,280 | Implemented |
MA0700 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,503 | $500 | Implemented |
MA0696 # 09 Y:2012 | 09 | 2012 | INSULATE BARE EQUIPMENT | $622 | $1,100 | Not Implemented |
MA0696 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $1,705 | $4,080 | Implemented |
MA0696 # 07 Y:2012 | 07 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,810 | $200 | Implemented |
MA0696 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,462 | $6,035 | Not Implemented |
MA0696 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,048 | $6,600 | Implemented |
MA0696 # 04 Y:2012 | 04 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,539 | $17,500 | Not Implemented |
MA0696 # 03 Y:2012 | 03 | 2012 | USE OPTIMUM TEMPERATURE | $6,647 | $4,000 | Not Implemented |
MA0696 # 02 Y:2012 | 02 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $15,781 | $2,800 | Implemented |
MA0696 # 01 Y:2012 | 01 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $19,393 | $39,000 | Implemented |