Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
86
matching recommendationsSIC | 329 | Misc. Nonmetallic Mineral Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0927 # 05 Y:2019 | 05 | 2019 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $308,141 | $1,725,000 | Not Implemented |
GT0927 # 03 Y:2019 | 03 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,382 | $27,983 | Implemented |
GT0927 # 04 Y:2019 | 04 | 2019 | INSULATE BARE EQUIPMENT | $5,352 | $6,398 | Implemented |
GT0927 # 06 Y:2019 | 06 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $62,369 | $548,847 | Not Implemented |
GT0927 # 01 Y:2019 | 01 | 2019 | INSTALL OCCUPANCY SENSORS | $32,534 | $4,145 | Implemented |
GT0927 # 02 Y:2019 | 02 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,930 | $2,500 | Implemented |
GT0878 # 03 Y:2011 | 03 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $42,919 | $63,600 | Not Implemented |
GT0878 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,600 | $8,000 | Implemented |
GT0878 # 02 Y:2011 | 02 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $77,000 | $12,000 | Not Implemented |
GT0847 # 06 Y:2008 | 06 | 2008 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $22,551 | $68,143 | Not Implemented |
GT0847 # 03 Y:2008 | 03 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $798,070 | $1,116,000 | Not Implemented |
GT0847 # 01 Y:2008 | 01 | 2008 | USE BUILDING MATERIALS WHICH REQUIRE LESS ENERGY TO PRODUCE | $153,731 | $0 | Not Implemented |
GT0847 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $40,596 | $8,400 | Not Implemented |
GT0847 # 04 Y:2008 | 04 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $788,500 | $514,500 | Not Implemented |
GT0847 # 02 Y:2008 | 02 | 2008 | REUSE SCRAP GLASS AS FEED STOCK | $729,921 | $850,000 | Implemented |
GT0762 # 09 Y:2003 | 09 | 2003 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $711,000 | $500,000 | Implemented |
GT0762 # 11 Y:2003 | 11 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $210,205 | $2,700,000 | Not Implemented |
GT0762 # 08 Y:2003 | 08 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $18,580 | $19,500 | Not Implemented |
GT0762 # 03 Y:2003 | 03 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,072 | $1,430 | Implemented |
GT0762 # 02 Y:2003 | 02 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $12,813 | $700 | Implemented |
GT0762 # 10 Y:2003 | 10 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $126,034 | $1,000,000 | Implemented |
GT0762 # 07 Y:2003 | 07 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,070 | $160 | Not Implemented |
GT0762 # 01 Y:2003 | 01 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $153,000 | $0 | Not Implemented |
GT0762 # 04 Y:2003 | 04 | 2003 | USE SYNTHETIC LUBRICANT | $24,255 | $0 | Implemented |
GT0762 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $20,544 | $32,000 | Not Implemented |