Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
281
matching recommendationsSIC | 3295 | Minerals, Ground Or Treated |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0489 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $2,780 | $1,760 | Not Implemented |
CO0489 # 04 Y:2001 | 04 | 2001 | INSULATE BARE EQUIPMENT | $1,500 | $630 | Implemented |
CO0489 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,290 | $0 | Implemented |
CO0489 # 06 Y:2001 | 06 | 2001 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,130 | $2,170 | Not Implemented |
CO0489 # 07 Y:2001 | 07 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $15,440 | $0 | Implemented |
CO0489 # 08 Y:2001 | 08 | 2001 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $4,360 | $4,000 | Implemented |
UF0269 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $775 | $1,200 | Implemented |
UF0269 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $706 | $410 | Implemented |
UF0269 # 03 Y:2001 | 03 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,613 | $64,742 | Implemented |
UF0269 # 04 Y:2001 | 04 | 2001 | ADD AREA LIGHTING SWITCHES | $2,086 | $2,358 | Implemented |
UF0269 # 05 Y:2001 | 05 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $314 | $75 | Implemented |
UF0269 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $20,239 | $2,500 | Implemented |
UF0269 # 07 Y:2001 | 07 | 2001 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $5,760 | $3,985 | Implemented |
UF0269 # 08 Y:2001 | 08 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $316 | $1,895 | Implemented |
UF0269 # 09 Y:2001 | 09 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $10,697 | $0 | Not Implemented |
UF0269 # 10 Y:2001 | 10 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $777 | $525 | Not Implemented |
SD0257 # 01 Y:2000 | 01 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $32,196 | $16,750 | Not Implemented |
SD0257 # 02 Y:2000 | 02 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $21,676 | $27,000 | Implemented |
SD0257 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,428 | $6,300 | Implemented |
SD0257 # 04 Y:2000 | 04 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,271 | $3,000 | Implemented |
SD0257 # 05 Y:2000 | 05 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,428 | $5,400 | Implemented |
SD0257 # 06 Y:2000 | 06 | 2000 | RECYCLE CLEANING SOLVENT AND REUSE | $2,345 | $0 | Implemented |
SD0257 # 07 Y:2000 | 07 | 2000 | RECOVER AND REUSE COOLING WATER | $7,795 | $2,000 | Implemented |
SD0257 # 08 Y:2000 | 08 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,760 | $0 | Implemented |
SD0257 # 09 Y:2000 | 09 | 2000 | AUTOMATE FINISHING PROCESS | $67,234 | $55,000 | Implemented |