Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
274
matching recommendationsSIC | 3296 | Mineral Wool |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0016 # 05 Y:1994 | 05 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $35,685 | $100,000 | Not Implemented |
SF0016 # 06 Y:1994 | 06 | 1994 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,290 | $0 | Implemented |
SF0016 # 07 Y:1994 | 07 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $55,136 | $55,428 | Not Implemented |
SF0016 # 08 Y:1994 | 08 | 1994 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,496 | $0 | Not Implemented |
SF0016 # 09 Y:1994 | 09 | 1994 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $793,437 | $1,350,000 | Not Implemented |
OR0176 # 01 Y:1993 | 01 | 1993 | INSULATE BARE EQUIPMENT | $576 | $0 | Implemented |
OR0176 # 02 Y:1993 | 02 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,144 | $23,450 | Not Implemented |
OR0176 # 03 Y:1993 | 03 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $270 | $0 | Implemented |
OR0176 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,776 | $2,859 | Implemented |
OR0176 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,174 | $9,100 | Not Implemented |
OR0176 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,712 | $2,537 | Implemented |
OR0176 # 07 Y:1993 | 07 | 1993 | OPTIMIZE PLANT POWER FACTOR | $9,930 | $21,000 | Not Implemented |
MO0085 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,076 | $29,223 | Implemented |
MO0085 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,889 | $2,140 | Implemented |
MO0085 # 03 Y:1993 | 03 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $962 | $398 | Not Implemented |
MO0085 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,575 | $11,052 | Implemented |
MO0085 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,509 | $504 | Implemented |
MO0085 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,151 | $1,835 | Implemented |
MO0085 # 07 Y:1993 | 07 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,776 | $366 | Implemented |
SD0037 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $943 | $4,020 | Implemented |
SD0037 # 02 Y:1992 | 02 | 1992 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $64,662 | $30,000 | Not Implemented |
SD0037 # 03 Y:1992 | 03 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,542 | $5,000 | Not Implemented |
SD0037 # 04 Y:1992 | 04 | 1992 | INSULATE BARE EQUIPMENT | $2,021 | $1,042 | Not Implemented |
SD0037 # 05 Y:1992 | 05 | 1992 | INSULATE BARE EQUIPMENT | $2,584 | $1,277 | Not Implemented |
SD0037 # 06 Y:1992 | 06 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $566 | $20 | Implemented |