Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

274

matching recommendations
Reset
SIC 3296 Mineral Wool
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0145 # 15 Y:1998 15 1998 INSULATE BARE EQUIPMENT $2,343 $833 Implemented
WV0145 # 16 Y:1998 16 1998 INSULATE BARE EQUIPMENT $527 $160 Implemented
WV0145 # 17 Y:1998 17 1998 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $1,559 $570 Not Implemented
WV0145 # 18 Y:1998 18 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $162,751 $0 Not Implemented
WV0145 # 19 Y:1998 19 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $92,886 $11,000 Implemented
WV0145 # 20 Y:1998 20 1998 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $122 $0 Not Implemented
WV0145 # 21 Y:1998 21 1998 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $18,689 $16,000 Implemented
WV0145 # 22 Y:1998 22 1998 RECOVER AND REUSE COOLING WATER $12,280 $6,200 Not Implemented
WV0145 # 23 Y:1998 23 1998 $301,000 $71,000 Not Implemented
NC0148 # 01 Y:1998 01 1998 RECOVER WASTE HEAT FROM EQUIPMENT $2,914 $10,000 Not Implemented
NC0148 # 02 Y:1998 02 1998 REDUCE FLUID FLOW RATES $304 $550 Implemented
NC0148 # 03 Y:1998 03 1998 $7,677 $10,000 Implemented
NC0148 # 04 Y:1998 04 1998 $63,429 $80,000 Implemented
ND0299 # 01 Y:1998 01 1998 PREHEAT COMBUSTION AIR WITH WASTE HEAT $18,816 $40,000 Not Implemented
ND0299 # 02 Y:1998 02 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,866 $180 Implemented
ND0299 # 03 Y:1998 03 1998 $1,351 $250 Implemented
ND0299 # 04 Y:1998 04 1998 $1,000 $50 Implemented
ND0299 # 05 Y:1998 05 1998 DISCONNECT BALLASTS $629 $792 Implemented
ND0299 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $489 $1,696 Implemented
ND0299 # 07 Y:1998 07 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $455 $130 Implemented
ND0299 # 08 Y:1998 08 1998 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $380 $1,715 Not Implemented
ND0299 # 09 Y:1998 09 1998 $329 $0 Not Implemented
ND0299 # 10 Y:1998 10 1998 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $266 $1,008 Not Implemented
ND0299 # 11 Y:1998 11 1998 INSTALL SKYLIGHTS $672 $223 Not Implemented
ND0299 # 12 Y:1998 12 1998 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $80 $50 Implemented