Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1998 |
Principal Product | Ceiling tile |
NAICS | n/a |
SIC | 3296 - Mineral Wool |
Sales | $50,000,000-$100,000,000 |
# of Employees | 170 |
Plant Area (Sq.Ft.) | 276,000 |
Annual Production | 45,000,000 Pieces |
Production Hrs. Annual | 8,400 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $943,860 | 14,043,670 | kWh | $0.07 |
Electricity Demand | $408,310 | 27,963 | kW-months/year | $14.60 |
Natural Gas | $965,647 | 229,227 | MMBtu | $4.21 |
TOTAL ENERGY COSTS | $2,317,817 | |||
RECOMMENDED SAVINGS* | $1,184,876 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $134,283 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes | Electricity Usage | Natural Gas | Other Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,801 Cost: $1,250 |
$2,801 | 73,271 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$2,801 73,271 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,143 Cost: $734 |
- | - | $4,143 | 984 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$4,143 984 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $2,936 Cost: $1,000 |
- | - | $2,936 | 697 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$2,936 697 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $595 Cost: $1,440 |
- | - | $595 | 53 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$595 53 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,410 Cost: $340 |
$1,410 | 36,928 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$1,410 36,928 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $9,068 Cost: $3,700 |
- | - | $9,068 | 2,154 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$9,068 2,154 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $516 Cost: - |
$516 | 13,482 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$516 13,482 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,635 Cost: $7,710 |
- | - | $2,635 | 626 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$2,635 626 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,762 Cost: $11,820 |
$5,762 | 150,645 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$5,762 150,645 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7122 DISCONNECT BALLASTS |
Savings: $3,120 Cost: $1,530 |
$3,120 | 81,770 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$3,120 81,770 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,076 Cost: $500 |
$1,076 | 28,136 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$1,076 28,136 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $13,250 Cost: $12,000 |
- | - | - | - | $13,250 | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - MMBtu |
$13,250 - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $543,058 Cost: $2,440,200 |
$543,058 | 9,766,413 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$543,058 9,766,413 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,349 Cost: $1,365 |
- | - | $2,349 | 558 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$2,349 558 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,343 Cost: $833 |
- | - | $2,343 | 556 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$2,343 556 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $527 Cost: $160 |
- | - | $527 | 125 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$527 125 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 2.1114 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE |
Savings: $1,559 Cost: $570 |
- | - | $1,559 | 370 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$1,559 370 MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
18: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $162,751 Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $162,751 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
$162,751 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
19: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $92,886 Cost: $11,000 |
- | - | - | - | - | - | - | - | - | - | $92,886 | - | - | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
$92,886 - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
20: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $122 Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | $122 | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
$122 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
21: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $18,689 Cost: $16,000 |
- | - | - | - | - | - | - | - | $18,689 | - | - | - | - | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
$18,689 - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
22: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $12,280 Cost: $6,200 |
- | - | - | - | - | - | $12,280 | 4,992,000 | - | - | - | - | - | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$12,280 4,992,000 Tgal |
- - gal |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
23: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $301,000 Cost: $71,000 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $301,000 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - lb |
$301,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,184,876 Cost: $2,589,352 |
$557,743 | 10,150,645 | $26,155 | 6,123 | $13,250 | - | $12,280 | 4,992,000 | $18,689 | - | $92,886 | - | $122 | - | $463,751 | - | $557,743 10,150,645 kWh |
$26,155 6,123 MMBtu |
$13,250 - MMBtu |
$12,280 4,992,000 Tgal |
$18,689 - gal |
$92,886 - lb |
$122 - lb |
$463,751 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $134,283 Cost: $44,827 |
$12,759 | 333,822 | $9,949 | 2,362 | - | - | - | - | $18,689 | - | $92,886 | - | - | - | - | - | $12,759 333,822 kWh |
$9,949 2,362 MMBtu |
- - MMBtu |
- - Tgal |
$18,689 - gal |
$92,886 - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes | Electricity Usage | Natural Gas | Other Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes |