Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
197
matching recommendationsSIC | 3296 | Mineral Wool |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0362 # 12 Y:2007 | 12 | 2007 | INSULATE BARE EQUIPMENT | $1,295 | $740 | Implemented |
WV0362 # 01 Y:2007 | 01 | 2007 | INSULATE BARE EQUIPMENT | $80,064 | $26,135 | Not Implemented |
WV0362 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,748 | $660 | Not Implemented |
WV0362 # 03 Y:2007 | 03 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,679 | $2,000 | Not Implemented |
WV0362 # 05 Y:2007 | 05 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,397 | $0 | Implemented |
WV0362 # 02 Y:2007 | 02 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,461 | $13,900 | Not Implemented |
WV0362 # 07 Y:2007 | 07 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,693 | $1,500 | Implemented |
WV0362 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,521 | $978 | Implemented |
WV0362 # 09 Y:2007 | 09 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,851 | $1,000 | Implemented |
WV0362 # 11 Y:2007 | 11 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,387 | $224 | Not Implemented |
WV0362 # 08 Y:2007 | 08 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $1,851 | $185 | Implemented |
WV0362 # 14 Y:2007 | 14 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $297 | $400 | Implemented |
WV0362 # 13 Y:2007 | 13 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $913 | $20 | Implemented |
WV0362 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,787 | $0 | Implemented |
AS0429 # 01 Y:2006 | 01 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,688 | $1,000 | n/a |
AS0429 # 04 Y:2006 | 04 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $34 | $3,200 | n/a |
AS0429 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,127 | $1,000 | n/a |
AS0429 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $2,039 | $500 | n/a |
AS0428 # 08 Y:2006 | 08 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $475 | $4,000 | n/a |
AS0428 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $614 | $300 | n/a |
AS0428 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,348 | $5,000 | n/a |
AS0428 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,252 | $1,500 | n/a |
AS0428 # 04 Y:2006 | 04 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,269 | $5,600 | n/a |
AS0428 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,918 | $2,500 | n/a |
AS0428 # 02 Y:2006 | 02 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,791 | $1,000 | n/a |