Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

83

matching recommendations
Reset
SIC 3297 Nonclay Refractories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0825 # 02 Y:2010 02 2010 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,976 $2,000 Not Implemented
UD0825 # 10 Y:2010 10 2010 RECOVER WASTE HEAT FROM EQUIPMENT $5,151 $1,200 Not Implemented
UD0825 # 01 Y:2010 01 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,398 $100 Not Implemented
WV0348 # 15 Y:2006 15 2006 DEVELOP A REPAIR/REPLACE POLICY $866 $680 Implemented
WV0348 # 14 Y:2006 14 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,057 $390 Implemented
WV0348 # 13 Y:2006 13 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,081 $1,100 Not Implemented
WV0348 # 12 Y:2006 12 2006 INSTALL OCCUPANCY SENSORS $1,202 $270 Not Implemented
WV0348 # 11 Y:2006 11 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,274 $470 Not Implemented
WV0348 # 10 Y:2006 10 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,322 $560 Implemented
WV0348 # 09 Y:2006 09 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,346 $2,540 Not Implemented
WV0348 # 08 Y:2006 08 2006 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $1,808 $1,000 Implemented
WV0348 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,260 $0 Implemented
WV0348 # 06 Y:2006 06 2006 REDUCE VENTILATION AIR $4,100 $6,800 Not Implemented
WV0348 # 05 Y:2006 05 2006 RECOVER WASTE HEAT FROM EQUIPMENT $7,373 $13,940 Not Implemented
WV0348 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,642 $8,678 Implemented
WV0348 # 03 Y:2006 03 2006 REDUCE VENTILATION AIR $10,762 $18,600 Not Implemented
WV0348 # 02 Y:2006 02 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $14,538 $3,000 Implemented
WV0348 # 01 Y:2006 01 2006 PREHEAT COMBUSTION AIR WITH WASTE HEAT $22,813 $25,350 Implemented
WV0348 # 16 Y:2006 16 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $545 $266 Implemented
WV0348 # 17 Y:2006 17 2006 RECOVER WASTE HEAT FROM EQUIPMENT $528 $880 Not Implemented
WV0114 # 04 Y:1997 04 1997 USE SYNTHETIC LUBRICANT $422 $640 Not Implemented
WV0114 # 08 Y:1997 08 1997 $426,660 $121,000 Not Implemented
WV0114 # 07 Y:1997 07 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,760 $590 Implemented
WV0114 # 06 Y:1997 06 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $900 $5,000 Not Implemented
WV0114 # 05 Y:1997 05 1997 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $10,136 $43,250 Not Implemented