Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
197
matching recommendationsSIC | 3299 | Nonmetallic Mineral Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CW0116 # 05 Y:2020 | 05 | 2020 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $4,030 | $19,360 | Not Implemented |
CW0116 # 04 Y:2020 | 04 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $46 | $0 | Implemented |
CW0116 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $138 | $90 | Implemented |
CW0116 # 02 Y:2020 | 02 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $752 | $70 | Implemented |
CW0116 # 01 Y:2020 | 01 | 2020 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $342 | $1,350 | Not Implemented |
SD0519 # 03 Y:2015 | 03 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,091 | $8,805 | Not Implemented |
SD0519 # 02 Y:2015 | 02 | 2015 | USE POWER DURING OFF-PEAK PERIODS | $15,251 | $10,325 | Implemented |
SD0519 # 04 Y:2015 | 04 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,983 | $16,500 | Implemented |
SD0519 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,572 | $1,500 | Implemented |
SD0519 # 01 Y:2015 | 01 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $15,876 | $6,475 | Implemented |
SD0519 # 05 Y:2015 | 05 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $3,856 | $210 | Implemented |
MA0714 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,354 | $9,300 | Not Implemented |
MA0714 # 05 Y:2013 | 05 | 2013 | INSULATE BARE EQUIPMENT | $4,187 | $7,500 | Not Implemented |
MA0714 # 01 Y:2013 | 01 | 2013 | BURN A LESS EXPENSIVE GRADE OF FUEL | $64,988 | $67,000 | Implemented |
MA0714 # 07 Y:2013 | 07 | 2013 | OPTIMIZE PLANT POWER FACTOR | $11,188 | $13,500 | Implemented |
MA0714 # 08 Y:2013 | 08 | 2013 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $1,360 | $150 | Implemented |
MA0714 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,362 | $13,800 | Implemented |
MA0714 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $4,919 | $12,300 | Not Implemented |
MA0714 # 02 Y:2013 | 02 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,831 | $5,568 | Implemented |
UK1311 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,284 | $88,771 | Implemented |
UK1311 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,665 | $200 | Implemented |
UK1311 # 06 Y:2013 | 06 | 2013 | INSTALL OCCUPANCY SENSORS | $2,760 | $3,342 | Not Implemented |
UK1311 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,278 | $27,331 | Implemented |
UK1311 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,500 | $5,600 | Implemented |
UK1311 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,537 | $1,340 | Implemented |