Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
492
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0248 # 08 Y:1996 | 08 | 1996 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $42,197 | $125,000 | Not Implemented |
ND0246 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $306 | $250 | Implemented |
ND0246 # 02 Y:1996 | 02 | 1996 | INSTALL OCCUPANCY SENSORS | $208 | $600 | Not Implemented |
ND0246 # 03 Y:1996 | 03 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14 | $252 | Not Implemented |
ND0246 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,011 | $570 | Implemented |
ND0246 # 05 Y:1996 | 05 | 1996 | OPTIMIZE PLANT POWER FACTOR | $7,672 | $6,376 | Not Implemented |
ND0246 # 06 Y:1996 | 06 | 1996 | TREAT AND REUSE RINSE WATERS | $1 | $0 | Implemented |
ND0232 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $580 | $200 | Implemented |
ND0232 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $3,800 | $6,240 | Not Implemented |
ND0232 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,328 | $250 | Not Implemented |
ND0232 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $320 | $800 | Not Implemented |
ND0232 # 05 Y:1995 | 05 | 1995 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $11,506 | $5,000 | Implemented |
ND0232 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,430 | $6,690 | Implemented |
ND0232 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $693 | $282 | Not Implemented |
ND0232 # 08 Y:1995 | 08 | 1995 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $7,136 | $44,552 | Implemented |
ND0217 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,328 | $7,375 | Implemented |
ND0217 # 02 Y:1995 | 02 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $858 | $0 | Implemented |
ND0217 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $445 | $1,200 | Implemented |
ND0217 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $440 | $100 | Implemented |
ND0217 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $250 | $200 | Implemented |
ND0217 # 06 Y:1995 | 06 | 1995 | INSTALL OCCUPANCY SENSORS | $168 | $800 | Implemented |
ND0217 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $111 | $390 | Implemented |
ND0217 # 08 Y:1995 | 08 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21 | $0 | Implemented |
ND0212 # 01 Y:1995 | 01 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $855 | $80 | Implemented |
ND0212 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $4,281 | $550 | Implemented |