Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
209
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0489 # 08 Y:2012 | 08 | 2012 | REDUCE VENTILATION AIR | $5,734 | $1,725 | Implemented |
IA0489 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,029 | $532 | Implemented |
IA0489 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,582 | $12,659 | Implemented |
IA0489 # 07 Y:2012 | 07 | 2012 | OPTIMIZE PLANT POWER FACTOR | $8,468 | $3,237 | Not Implemented |
IA0489 # 01 Y:2012 | 01 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,668 | $385 | Not Implemented |
IA0489 # 06 Y:2012 | 06 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,423 | $1,091 | Implemented |
IA0432 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $986 | $67 | Not Implemented |
IA0432 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $416 | $322 | Implemented |
IA0432 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,099 | $1,884 | Implemented |
IA0432 # 11 Y:2008 | 11 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,042 | $930 | Not Implemented |
IA0432 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $979 | $17 | Implemented |
IA0432 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $687 | $330 | Implemented |
IA0432 # 12 Y:2008 | 12 | 2008 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $2,480 | $5,333 | Implemented |
IA0432 # 09 Y:2008 | 09 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $571 | $1,650 | Implemented |
IA0432 # 07 Y:2008 | 07 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $423 | $143 | Implemented |
IA0432 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,859 | $620 | Implemented |
IA0432 # 10 Y:2008 | 10 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,529 | $1,781 | Not Implemented |
IA0432 # 08 Y:2008 | 08 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,295 | $3,442 | Not Implemented |
IA0412 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,305 | $2,775 | Implemented |
IA0412 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,880 | $104 | Implemented |
IA0412 # 09 Y:2007 | 09 | 2007 | REDUCE SCRAP PRODUCTION | $33,433 | $4,000 | Not Implemented |
IA0412 # 05 Y:2007 | 05 | 2007 | INSULATE BARE EQUIPMENT | $164 | $200 | Implemented |
IA0412 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,034 | $500 | Implemented |
IA0412 # 04 Y:2007 | 04 | 2007 | COVER OPEN TANKS | $143,500 | $22,000 | Implemented |
IA0412 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $671 | $1,925 | Not Implemented |