Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

494

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0365 # 02 Y:2010 02 2010 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $15,991 $107,000 Implemented
UM0365 # 03 Y:2010 03 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,966 $13,000 Implemented
UM0365 # 04 Y:2010 04 2010 INSTALL OCCUPANCY SENSORS $1,051 $0 Implemented
UM0365 # 05 Y:2010 05 2010 RECOVER WASTE HEAT FROM EQUIPMENT $43,773 $13,000 Implemented
UM0365 # 06 Y:2010 06 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,455 $3,500 Implemented
UM0365 # 07 Y:2010 07 2010 USE OPTIMUM THICKNESS INSULATION $1,040 $22,500 Implemented
UM0365 # 08 Y:2010 08 2010 INSTALL STORM WINDOWS AND DOORS $819 $0 Not Implemented
IC0163 # 02 Y:2009 02 2009 INSTALL OCCUPANCY SENSORS $635 $538 Implemented
IC0163 # 03 Y:2009 03 2009 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $3,314 $102 Implemented
IC0163 # 04 Y:2009 04 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $357 $0 Not Implemented
IC0163 # 05 Y:2009 05 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,247 $0 Not Implemented
IC0163 # 06 Y:2009 06 2009 USE RADIANT HEATER FOR SPOT HEATING $9,226 $39,560 Not Implemented
IC0163 # 07 Y:2009 07 2009 PREHEAT COMBUSTION AIR WITH WASTE HEAT $6,925 $17,000 Implemented
IC0163 # 08 Y:2009 08 2009 RECYCLE WHITE WATER $2,034 $771 Implemented
IC0163 # 09 Y:2009 09 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $260 $0 Not Implemented
IC0163 # 10 Y:2009 10 2009 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $1,689,703 $0 Implemented
IC0163 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $528 $332 Implemented
UM0338 # 01 Y:2008 01 2008 RECOVER WASTE HEAT FROM EQUIPMENT $30,146 $38,350 Not Implemented
UM0338 # 02 Y:2008 02 2008 RECOVER WASTE HEAT FROM EQUIPMENT $16,908 $4,000 Not Implemented
UM0338 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,301 $19,680 Not Implemented
UM0338 # 04 Y:2008 04 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,640 $1,400 Not Implemented
UM0338 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,107 $900 Not Implemented
UM0338 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,305 $4,480 Not Implemented
UM0338 # 07 Y:2008 07 2008 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES $257 $1,095 Not Implemented
UM0338 # 08 Y:2008 08 2008 INSTALL OCCUPANCY SENSORS $103 $270 Not Implemented