Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

241

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0101 # 04 Y:2001 04 2001 OPTIMIZE PLANT POWER FACTOR $2,500 $8,350 Not Implemented
RU0084 # 01 Y:1990 01 1990 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $68,217 $70,000 Implemented
RU0084 # 02 Y:1990 02 1990 CONSIDER THREE OR FOUR DAYS AROUND-THE-CLOCK OPERATION RATHER THAN ONE OR TWO SHIFTS PER DAY $12,691 $0 Not Implemented
RU0084 # 03 Y:1990 03 1990 USE OPTIMUM THICKNESS INSULATION $4,598 $3,900 Not Implemented
RU0041 # 01 Y:1988 01 1988 IMPROVE LUBRICATION PRACTICES $1,095 $800 Implemented
RU0041 # 02 Y:1988 02 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $905 $594 Not Implemented
RU0041 # 03 Y:1988 03 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,030 $0 Implemented
RU0041 # 04 Y:1988 04 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,086 $0 Implemented
RU0041 # 05 Y:1988 05 1988 INSULATE BARE EQUIPMENT $319 $73 Implemented
RU0041 # 06 Y:1988 06 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,907 $2,500 Not Implemented
RU0041 # 07 Y:1988 07 1988 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,296 $420 Not Implemented
ST0080 # 01 Y:1986 01 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $18,901 $59,000 Not Implemented
ST0080 # 02 Y:1986 02 1986 RECOVER WASTE HEAT FROM EQUIPMENT $9,482 $7,000 Implemented
ST0080 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,370 $0 Implemented
ST0080 # 04 Y:1986 04 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $531 $1,333 Implemented
ST0080 # 05 Y:1986 05 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,206 $558 Implemented
ST0080 # 06 Y:1986 06 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,264 $2,016 Implemented
ST0080 # 07 Y:1986 07 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,682 $6,000 Not Implemented
ST0069 # 01 Y:1986 01 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,724 $0 Implemented
ST0069 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $604 $150 Implemented
ST0069 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,893 $269 Implemented
ST0069 # 04 Y:1986 04 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,839 $792 Implemented
ST0069 # 05 Y:1986 05 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $985 $2,700 Implemented
ST0069 # 06 Y:1986 06 1986 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $164 $0 Not Implemented
ST0069 # 07 Y:1986 07 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $225 $400 Not Implemented