IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

439

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0168 # 01 Y:2000 01 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $526 $993 Implemented
UM0168 # 02 Y:2000 02 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $15,117 $50,000 Not Implemented
UM0168 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,945 $2,250 Implemented
UM0168 # 04 Y:2000 04 2000 UPGRADE CONTROLS ON COMPRESSORS $8,180 $300 Implemented
UM0168 # 05 Y:2000 05 2000 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,403 $1,400 Not Implemented
UM0168 # 06 Y:2000 06 2000 RECOVER WASTE HEAT FROM EQUIPMENT $293,452 $1,020,000 Not Implemented
AM0378 # 01 Y:2000 01 2000 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $21,982 $6,500 Implemented
AM0378 # 02 Y:2000 02 2000 OPTIMIZE PLANT POWER FACTOR $18,650 $39,500 Implemented
AM0378 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,660 $500 Implemented
AM0378 # 04 Y:2000 04 2000 SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED $13,630 $699 Implemented
AM0378 # 05 Y:2000 05 2000 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $11,000 $1,350 Implemented
AM0378 # 06 Y:2000 06 2000 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $9,638 $0 Not Implemented
AM0378 # 07 Y:2000 07 2000 $4,000 $0 Implemented
AM0378 # 08 Y:2000 08 2000 SHIP HYDRAULIC OIL TO SECONDARY FUEL PROGRAM $3,610 $0 Implemented
AM0378 # 09 Y:2000 09 2000 $2,450 $0 Implemented
AM0378 # 10 Y:2000 10 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,390 $0 Not Implemented
AM0378 # 11 Y:2000 11 2000 INSTALL SPECTRAL REFLECTORS / DELAMP $2,310 $2,800 Implemented
AM0378 # 12 Y:2000 12 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $460 $250 Not Implemented
IA0256 # 01 Y:2000 01 2000 INSTALL OCCUPANCY SENSORS $9,747 $11,763 Not Implemented
IA0256 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,729 $0 Not Implemented
IA0256 # 03 Y:2000 03 2000 INSTALL OCCUPANCY SENSORS $623 $2,261 Not Implemented
IA0256 # 04 Y:2000 04 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,814 $346 Not Implemented
IA0256 # 05 Y:2000 05 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,685 $100 Implemented
IA0256 # 06 Y:2000 06 2000 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,621 $135 Implemented
IA0256 # 07 Y:2000 07 2000 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $122 $40 Implemented