Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
888
matching recommendationsSIC | 331 | Blast Furnace And Basic Steel Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0416 # 06 Y:1993 | 06 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $345 | $809 | Implemented |
KU0416 # 07 Y:1993 | 07 | 1993 | INSULATE BARE EQUIPMENT | $214 | $1,209 | Implemented |
WI0188 # 01 Y:1993 | 01 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,239 | $2,000 | Implemented |
WI0188 # 02 Y:1993 | 02 | 1993 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,978 | $600 | Implemented |
WI0188 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $556 | $1,600 | Implemented |
HO0050 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,748 | $2,605 | Implemented |
HO0050 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,764 | $3,483 | Implemented |
HO0050 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $319 | $285 | Implemented |
HO0050 # 04 Y:1993 | 04 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $809 | $300 | Implemented |
HO0050 # 05 Y:1993 | 05 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $67 | $204 | Implemented |
HO0050 # 06 Y:1993 | 06 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $834 | $40 | Implemented |
WV0011 # 03 Y:1993 | 03 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,265 | $4,110 | Implemented |
WV0011 # 05 Y:1993 | 05 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $51,421 | $28,120 | Implemented |
WV0011 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,643 | $3,362 | Implemented |
WV0011 # 08 Y:1993 | 08 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,798 | $12,730 | Implemented |
GT0495 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,080 | $14,170 | Implemented |
GT0495 # 05 Y:1993 | 05 | 1993 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $1,390 | $500 | Implemented |
AM0175 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $7,090 | $16,000 | Implemented |
AM0175 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $1,000 | Implemented |
AM0175 # 04 Y:1993 | 04 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $650 | $0 | Implemented |
AM0175 # 05 Y:1993 | 05 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $640 | $765 | Implemented |
AM0164 # 01 Y:1992 | 01 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $93,089 | $0 | Implemented |
AM0164 # 02 Y:1992 | 02 | 1992 | OPTIMIZE PLANT POWER FACTOR | $44,815 | $64,750 | Implemented |
AM0164 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,158 | $1,030 | Implemented |
AM0164 # 06 Y:1992 | 06 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,140 | $910 | Implemented |