Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,064

matching recommendations
Reset
SIC 331 Blast Furnace And Basic Steel Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0681 # 02 Y:2000 02 2000 $20,000 $16,083 Implemented
TN0681 # 03 Y:2000 03 2000 $11,200 $23,000 Implemented
TN0681 # 04 Y:2000 04 2000 DISCONNECT BALLASTS $6,170 $250 Not Implemented
TN0681 # 05 Y:2000 05 2000 RECOVER WASTE HEAT FROM EQUIPMENT $3,865 $9,000 Not Implemented
TN0681 # 06 Y:2000 06 2000 COVER OPEN TANKS $2,400 $1,700 Not Implemented
OK0589 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,862 $1,900 Implemented
OK0589 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,093 $4,942 Implemented
OK0589 # 03 Y:2000 03 2000 USE PHOTOCELL CONTROLS $504 $136 Implemented
OK0589 # 04 Y:2000 04 2000 $72,000 $230,000 Implemented
OK0589 # 05 Y:2000 05 2000 RECOVER AND REUSE WASTE MATERIAL $20,274 $59,400 Implemented
UL0238 # 01 Y:2000 01 2000 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $6,743 $0 Not Implemented
UL0238 # 02 Y:2000 02 2000 DISCONNECT BALLASTS $12,291 $1,236 Implemented
UL0238 # 03 Y:2000 03 2000 $15,288 $80,000 Not Implemented
ND0341 # 01 Y:1999 01 1999 DEVELOP A REPAIR/REPLACE POLICY $22,377 $60,343 Not Implemented
ND0341 # 02 Y:1999 02 1999 INSTALL OCCUPANCY SENSORS $128 $200 Not Implemented
ND0341 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $344 $180 Implemented
ND0341 # 04 Y:1999 04 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3 $300 Not Implemented
ND0341 # 05 Y:1999 05 1999 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,719 $250 Implemented
ND0341 # 06 Y:1999 06 1999 $-177 $336 Not Implemented
ND0341 # 07 Y:1999 07 1999 $9,218 $250 Not Implemented
ND0341 # 08 Y:1999 08 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $90,862 $120,000 Not Implemented
MS0147 # 01 Y:1999 01 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $15,658 $1,110 Implemented
MS0147 # 02 Y:1999 02 1999 INSTALL TIMERS AND/OR THERMOSTATS $1,258 $708 Implemented
MS0147 # 03 Y:1999 03 1999 INSTALL OCCUPANCY SENSORS $1,733 $798 Not Implemented
MS0147 # 04 Y:1999 04 1999 SHUT OFF PILOTS IN STANDBY EQUIPMENT $1,128 $20 Implemented