Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
75
matching recommendationsSIC | 331 | Blast Furnace And Basic Steel Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0950 # 03 Y:2016 | 03 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $20,070 | $1,790 | Not Implemented |
OK0950 # 06 Y:2016 | 06 | 2016 | OPTIMIZE PLANT POWER FACTOR | $3,100 | $13,740 | Not Implemented |
OK0950 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,777 | $12,727 | Not Implemented |
OK0950 # 04 Y:2016 | 04 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,968 | $666 | Not Implemented |
OK0950 # 05 Y:2016 | 05 | 2016 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $9,245 | $100 | Not Implemented |
OK0950 # 02 Y:2016 | 02 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $22,408 | $2,125 | Not Implemented |
TT0180 # 01 Y:2016 | 01 | 2016 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $27,451 | $700 | Implemented |
TT0180 # 05 Y:2016 | 05 | 2016 | INSTALL COMMON HEADER ON COMPRESSORS | $8,381 | $11,700 | Implemented |
TT0180 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $27,289 | $0 | Implemented |
TT0180 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,241 | $2,500 | Implemented |
TT0180 # 08 Y:2016 | 08 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $2,047 | $1,575 | Implemented |
TT0180 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,587 | $100,037 | Implemented |
TT0180 # 03 Y:2016 | 03 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $25,771 | $40,000 | Implemented |
TT0180 # 06 Y:2016 | 06 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,293 | $10,800 | Not Implemented |
TT0180 # 09 Y:2016 | 09 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $408 | $661 | Not Implemented |
SD0536 # 10 Y:2016 | 10 | 2016 | INSTALL OCCUPANCY SENSORS | $1,296 | $3,200 | Implemented |
SD0536 # 09 Y:2016 | 09 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,472 | $200 | Not Implemented |
SD0536 # 08 Y:2016 | 08 | 2016 | INSULATE BARE EQUIPMENT | $1,796 | $2,742 | Implemented |
SD0536 # 07 Y:2016 | 07 | 2016 | USE PHOTOCELL CONTROLS | $2,367 | $3,700 | Not Implemented |
SD0536 # 06 Y:2016 | 06 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,995 | $648 | Implemented |
SD0536 # 05 Y:2016 | 05 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,594 | $11,180 | Not Implemented |
SD0536 # 04 Y:2016 | 04 | 2016 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $6,259 | $11,760 | Not Implemented |
SD0536 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,468 | $8,787 | Not Implemented |
SD0536 # 02 Y:2016 | 02 | 2016 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $23,163 | $68,259 | Not Implemented |
SD0536 # 01 Y:2016 | 01 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $91,093 | $350,298 | Not Implemented |