Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 3312 | Blast Furnaces And Steel Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0835 # 02 Y:2022 | 02 | 2022 | OPTIMIZE PLANT POWER FACTOR | $4,178 | $15,055 | Implemented |
AM0835 # 07 Y:2022 | 07 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $243 | $308 | Implemented |
AM0835 # 05 Y:2022 | 05 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $810 | $0 | Implemented |
AM0835 # 01 Y:2022 | 01 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,925 | $2,265 | Implemented |
AM0835 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,885 | $8,600 | Implemented |
AM0835 # 03 Y:2022 | 03 | 2022 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,870 | $0 | Implemented |
AM0835 # 06 Y:2022 | 06 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $310 | $36 | Implemented |
AM0691 # 07 Y:2015 | 07 | 2015 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $120 | $130 | Not Implemented |
AM0691 # 06 Y:2015 | 06 | 2015 | USE PHOTOCELL CONTROLS | $280 | $130 | Implemented |
AM0691 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $420 | $240 | Not Implemented |
AM0691 # 04 Y:2015 | 04 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $440 | $0 | Implemented |
AM0691 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,250 | $1,720 | Not Implemented |
AM0691 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,550 | $2,000 | Implemented |
AM0691 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,140 | $39,720 | Not Implemented |
AM0644 # 06 Y:2013 | 06 | 2013 | PAY BILLS ON TIME TO AVOID LATE FEES | $24,370 | $0 | Implemented |
AM0644 # 09 Y:2013 | 09 | 2013 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $390 | $525 | Implemented |
AM0644 # 08 Y:2013 | 08 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,190 | $0 | Implemented |
AM0644 # 07 Y:2013 | 07 | 2013 | INSTALL SKYLIGHTS | $11,090 | $7,840 | Not Implemented |
AM0644 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $29,120 | $50 | Implemented |
AM0644 # 04 Y:2013 | 04 | 2013 | OPTIMIZE PLANT POWER FACTOR | $43,700 | $147,000 | Implemented |
AM0644 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $45,950 | $50,800 | Implemented |
AM0644 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $51,450 | $2,000 | Implemented |
AM0644 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $211,550 | $5,000 | Implemented |
AM0636 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,670 | $2,595 | Not Implemented |
AM0636 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,600 | $900 | Implemented |