Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

16

matching recommendations
Reset
SIC 3313 Electrometallurgical Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL2417 # 01 Y:2024 01 2024 USE SOLAR HEAT TO MAKE ELECTRICTY $55,561 $524,124 n/a
UL2417 # 02 Y:2024 02 2024 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $12,753 $43,234 n/a
UL2417 # 03 Y:2024 03 2024 RECOVER WASTE HEAT FROM EQUIPMENT $12,850 $39,000 n/a
UL2417 # 04 Y:2024 04 2024 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,595 $5,797 n/a
UL2417 # 05 Y:2024 05 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $463 $0 n/a
UL2417 # 06 Y:2024 06 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,025 $525 n/a
UL2417 # 07 Y:2024 07 2024 INSTALL SPECTRAL REFLECTORS / DELAMP $900 $0 n/a
UL2417 # 08 Y:2024 08 2024 INSTALL OCCUPANCY SENSORS $438 $941 n/a
WV0011 # 01 Y:1993 01 1993 RECOVER WASTE HEAT FROM EQUIPMENT $2,345 $2,613 Not Implemented
WV0011 # 02 Y:1993 02 1993 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $18,346 $6,950 Not Implemented
WV0011 # 03 Y:1993 03 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,265 $4,110 Implemented
WV0011 # 04 Y:1993 04 1993 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $27,112 $1,450 Not Implemented
WV0011 # 05 Y:1993 05 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $51,421 $28,120 Implemented
WV0011 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $551 $247 Not Implemented
WV0011 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,643 $3,362 Implemented
WV0011 # 08 Y:1993 08 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,798 $12,730 Implemented