Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

38

matching recommendations
Reset
SIC 3315 Steel Wire And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0700 # 06 Y:2004 06 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,941 $0 Not Implemented
UD0700 # 07 Y:2004 07 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,656 $3,000 Not Implemented
UD0700 # 08 Y:2004 08 2004 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $2,312 $8,302 Not Implemented
UD0700 # 09 Y:2004 09 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,471 $4,116 Not Implemented
UD0700 # 10 Y:2004 10 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,258 $1,405 Not Implemented
UD0700 # 11 Y:2004 11 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,104 $700 Not Implemented
UD0554 # 01 Y:1998 01 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $101,400 $60,000 Not Implemented
UD0554 # 07 Y:1998 07 1998 COVER OPEN TANKS $2,023 $1,050 Implemented
UD0554 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,699 $6,419 Not Implemented
UD0554 # 05 Y:1998 05 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $4,026 $1,850 Implemented
UD0554 # 04 Y:1998 04 1998 INSULATE BARE EQUIPMENT $19,707 $21,120 Not Implemented
UD0554 # 03 Y:1998 03 1998 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $28,560 $8,000 Implemented
UD0554 # 02 Y:1998 02 1998 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $47,736 $2,000 Not Implemented