Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,069
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0329 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $76,610 | $25,300 | Not Implemented |
LE0329 # 02 Y:2011 | 02 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $50,301 | $8,250 | Not Implemented |
LE0329 # 03 Y:2011 | 03 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,228 | $86,000 | Not Implemented |
LE0329 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,539 | $30,000 | Not Implemented |
LE0329 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,298 | $1,000 | Not Implemented |
BD0398 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,226 | $1,200 | Not Implemented |
BD0398 # 02 Y:2011 | 02 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,047 | $6,500 | Not Implemented |
BD0398 # 03 Y:2011 | 03 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,303 | $4,303 | Not Implemented |
BD0398 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,216 | $2,274 | Not Implemented |
BD0398 # 05 Y:2011 | 05 | 2011 | USE SYNTHETIC LUBRICANT | $2,370 | $300 | Not Implemented |
NC0439 # 01 Y:2011 | 01 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $37,298 | $27,675 | Not Implemented |
NC0439 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,669 | $39,646 | Implemented |
NC0439 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $330 | $106 | Implemented |
NC0439 # 04 Y:2011 | 04 | 2011 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,390 | $4,200 | Implemented |
NC0439 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $4,934 | $2,393 | Implemented |
NC0439 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,486 | $1,800 | Not Implemented |
NC0439 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,953 | $100 | Implemented |
MA0678 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,383 | $88,700 | Implemented |
MA0678 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,204 | $5,760 | Implemented |
MA0678 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,343 | $0 | Implemented |
MA0678 # 04 Y:2011 | 04 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,186 | $0 | Implemented |
MA0678 # 05 Y:2011 | 05 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,819 | $26,495 | Not Implemented |
MA0678 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,833 | $8,590 | Not Implemented |
UW0052 # 01 Y:2011 | 01 | 2011 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $43,653 | $0 | Not Implemented |
UW0052 # 02 Y:2011 | 02 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $26,448 | $326,103 | Not Implemented |