Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,069
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0004 # 08 Y:2007 | 08 | 2007 | UPGRADE OBSOLETE EQUIPMENT | $47,141 | $67,908 | Not Implemented |
UA0004 # 09 Y:2007 | 09 | 2007 | USE OPTIMUM THICKNESS INSULATION | $17,420 | $1,926 | Not Implemented |
UA0004 # 10 Y:2007 | 10 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,180 | $2,897 | Not Implemented |
UA0004 # 11 Y:2007 | 11 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,282 | $0 | Not Implemented |
IC0128 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,654 | $1,710 | Implemented |
IC0128 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,523 | $6,000 | Not Implemented |
IC0128 # 03 Y:2007 | 03 | 2007 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $25,162 | $21,540 | Implemented |
IC0128 # 04 Y:2007 | 04 | 2007 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $103,122 | $9,600 | Not Implemented |
IC0128 # 05 Y:2007 | 05 | 2007 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $44,610 | $0 | Not Implemented |
IC0128 # 06 Y:2007 | 06 | 2007 | IMPROVE SPACE COMFORT CONDITIONING | $11,886 | $10,408 | Not Implemented |
IC0128 # 07 Y:2007 | 07 | 2007 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $21,900 | $5,883 | Implemented |
IC0128 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,566 | $11,407 | Implemented |
IC0128 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $249 | $260 | Implemented |
IC0128 # 10 Y:2007 | 10 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,851 | $30,665 | Implemented |
LE0251 # 01 Y:2007 | 01 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $35,204 | $3,330 | Implemented |
LE0251 # 02 Y:2007 | 02 | 2007 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $21,905 | $15,088 | Not Implemented |
LE0251 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $18,340 | $24,000 | Implemented |
LE0251 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,085 | $1,000 | Implemented |
LE0251 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,122 | $194 | Implemented |
LE0251 # 06 Y:2007 | 06 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,198 | $7,003 | Not Implemented |
LE0251 # 07 Y:2007 | 07 | 2007 | OPTIMIZE PLANT POWER FACTOR | $3,551 | $4,650 | Not Implemented |
LE0251 # 08 Y:2007 | 08 | 2007 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $2,117 | $1,500 | Not Implemented |
LE0251 # 09 Y:2007 | 09 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $758 | $300 | Not Implemented |
LE0251 # 10 Y:2007 | 10 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $139 | $125 | Not Implemented |
BD0317 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $270,665 | $95,987 | Not Implemented |