Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
137
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0197 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,606 | $2,484 | Implemented |
LE0197 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $35,862 | $150,000 | Not Implemented |
LE0197 # 06 Y:2004 | 06 | 2004 | INSULATE FEEDWATER TANK | $22,098 | $50,000 | Not Implemented |
LE0197 # 07 Y:2004 | 07 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $864 | $840 | Implemented |
LE0131 # 01 Y:2002 | 01 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,624 | $0 | Implemented |
LE0131 # 02 Y:2002 | 02 | 2002 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $11,376 | $4,500 | Implemented |
LE0131 # 03 Y:2002 | 03 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,486 | $500 | Not Implemented |
LE0131 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $238 | $0 | Not Implemented |
LE0131 # 05 Y:2002 | 05 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,937 | $6,200 | Not Implemented |
LE0116 # 01 Y:2001 | 01 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,897 | $0 | Implemented |
LE0116 # 02 Y:2001 | 02 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $18,073 | $0 | Implemented |
LE0116 # 03 Y:2001 | 03 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,580 | $0 | Implemented |
LE0116 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $668 | $239 | Implemented |
LE0116 # 05 Y:2001 | 05 | 2001 | USE LESS WASTEFUL PACKAGING | $11,666 | $0 | Not Implemented |
LE0116 # 06 Y:2001 | 06 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $113 | $40 | Implemented |
LE0105 # 01 Y:2001 | 01 | 2001 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $2,453 | $245 | Not Implemented |
LE0105 # 02 Y:2001 | 02 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $674 | $0 | Not Implemented |
LE0105 # 03 Y:2001 | 03 | 2001 | BURN A LESS EXPENSIVE GRADE OF FUEL | $301 | $0 | Not Implemented |
LE0105 # 04 Y:2001 | 04 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,872 | $850 | Not Implemented |
LE0105 # 05 Y:2001 | 05 | 2001 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $4,880 | $1,200 | Not Implemented |
HO0222 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,727 | $8,392 | Implemented |
HO0222 # 02 Y:2000 | 02 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,554 | $21,600 | Not Implemented |
HO0222 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $697 | $600 | Implemented |
HO0222 # 04 Y:2000 | 04 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $14,666 | $0 | Not Implemented |
HO0222 # 05 Y:2000 | 05 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $723 | $4,000 | Implemented |