Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,049

matching recommendations
Reset
SIC 332 Iron And Steel Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0221 # 01 Y:1994 01 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $58,720 $80,000 Not Implemented
AM0221 # 02 Y:1994 02 1994 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,930 $0 Not Implemented
AM0221 # 03 Y:1994 03 1994 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $5,430 $0 Implemented
AM0221 # 04 Y:1994 04 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,180 $200 Implemented
AM0221 # 05 Y:1994 05 1994 RECYCLE CASTING SAND $37,570 $0 Implemented
AM0221 # 06 Y:1994 06 1994 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $1,040 $2,400 Not Implemented
AM0221 # 07 Y:1994 07 1994 RECYCLE CASTING SAND $63,410 $209,930 Not Implemented
IA0091 # 01 Y:1994 01 1994 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $64,093 $4,700 Implemented
IA0091 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,691 $9,871 Implemented
IA0091 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $527 $1,386 Not Implemented
IA0091 # 04 Y:1994 04 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,200 $150 Implemented
IA0091 # 05 Y:1994 05 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,028 $40 Implemented
IA0091 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,181 $1,168 Implemented
IA0091 # 07 Y:1994 07 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $805 $665 Not Implemented
IA0091 # 08 Y:1994 08 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $381 $0 Not Implemented
KU0436 # 01 Y:1994 01 1994 $20,016 $3,500 Implemented
KU0436 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,311 $11,979 Implemented
KU0436 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,311 $8,410 Not Implemented
KU0436 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,628 $3,559 Implemented
KU0436 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $961 $950 Not Implemented
KU0436 # 06 Y:1994 06 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,442 $155 Implemented
KU0436 # 07 Y:1994 07 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,335 $326 Implemented
KU0436 # 08 Y:1994 08 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,045 $765 Not Implemented
KU0436 # 09 Y:1994 09 1994 USE SYNTHETIC LUBRICANT $670 $510 Implemented
TN0529 # 01 Y:1994 01 1994 COVER OPEN TANKS $8,253 $100 Implemented