Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,069

matching recommendations
Reset
SIC 332 Iron And Steel Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0378 # 08 Y:1992 08 1992 IMPROVE LUBRICATION PRACTICES $3,215 $0 Not Implemented
KU0378 # 09 Y:1992 09 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,075 $0 Not Implemented
KU0378 # 10 Y:1992 10 1992 INSTALL TIMERS AND/OR THERMOSTATS $1,230 $1,505 Not Implemented
OR0162 # 01 Y:1992 01 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $289 $0 Not Implemented
OR0162 # 02 Y:1992 02 1992 TURN OFF EQUIPMENT WHEN NOT IN USE $5,784 $2,920 Implemented
OR0162 # 03 Y:1992 03 1992 USE DEMAND CONTROLLER OR LOAD SHEDDER $524 $750 Implemented
OR0162 # 04 Y:1992 04 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,666 $5,359 Implemented
OR0162 # 05 Y:1992 05 1992 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $4,388 $14,272 Not Implemented
OR0162 # 06 Y:1992 06 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $26,207 $150,000 Implemented
OR0162 # 07 Y:1992 07 1992 REDESIGN PROCESS $15,590 $130,000 Not Implemented
GT0473 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $390 $21,630 Not Implemented
GT0473 # 02 Y:1992 02 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $300 $0 Not Implemented
GT0473 # 03 Y:1992 03 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,770 $10,000 Not Implemented
GT0473 # 04 Y:1992 04 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $10,180 $9,000 Not Implemented
GT0473 # 05 Y:1992 05 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,040 $5,100 Not Implemented
GT0473 # 06 Y:1992 06 1992 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $200 $1,015 Not Implemented
MO0070 # 01 Y:1992 01 1992 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $64,793 $300 Not Implemented
MO0070 # 02 Y:1992 02 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $35,376 $200 Not Implemented
MO0070 # 03 Y:1992 03 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,537 $109,000 Not Implemented
MO0070 # 04 Y:1992 04 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,418 $265 Not Implemented
MO0070 # 05 Y:1992 05 1992 IMPROVE LUBRICATION PRACTICES $11,792 $0 Not Implemented
MO0070 # 06 Y:1992 06 1992 RECOVER AND REUSE COOLING WATER $8,112 $0 Not Implemented
MO0070 # 07 Y:1992 07 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,709 $18,500 Not Implemented
MO0070 # 08 Y:1992 08 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,044 $1,000 Not Implemented
MA0232 # 01 Y:1992 01 1992 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $31,842 $90,600 Not Implemented