Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsSIC | 3321 | Gray And Ductile Iron Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0353 # 09 Y:2013 | 09 | 2013 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,051,434 | $5,225,000 | Not Implemented |
LE0353 # 08 Y:2013 | 08 | 2013 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $1,196 | $2,200 | Implemented |
LE0353 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,835 | $1,000 | Implemented |
LE0353 # 06 Y:2013 | 06 | 2013 | INSULATE BARE EQUIPMENT | $15,964 | $6,384 | Not Implemented |
LE0353 # 05 Y:2013 | 05 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $13,908 | $2,800 | Not Implemented |
LE0353 # 04 Y:2013 | 04 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,843 | $520 | Implemented |
LE0353 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,998 | $11,700 | Implemented |
LE0353 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $786 | $3,495 | Implemented |
LE0353 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,972 | $8,105 | Implemented |
LE0329 # 02 Y:2011 | 02 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $50,301 | $8,250 | Not Implemented |
LE0329 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $76,610 | $25,300 | Not Implemented |
LE0329 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,298 | $1,000 | Not Implemented |
LE0329 # 03 Y:2011 | 03 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,228 | $86,000 | Not Implemented |
LE0329 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,539 | $30,000 | Not Implemented |
LE0251 # 10 Y:2007 | 10 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $139 | $125 | Not Implemented |
LE0251 # 01 Y:2007 | 01 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $35,204 | $3,330 | Implemented |
LE0251 # 02 Y:2007 | 02 | 2007 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $21,905 | $15,088 | Not Implemented |
LE0251 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $18,340 | $24,000 | Implemented |
LE0251 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,085 | $1,000 | Implemented |
LE0251 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,122 | $194 | Implemented |
LE0251 # 07 Y:2007 | 07 | 2007 | OPTIMIZE PLANT POWER FACTOR | $3,551 | $4,650 | Not Implemented |
LE0251 # 09 Y:2007 | 09 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $758 | $300 | Not Implemented |
LE0251 # 06 Y:2007 | 06 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,198 | $7,003 | Not Implemented |
LE0251 # 08 Y:2007 | 08 | 2007 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $2,117 | $1,500 | Not Implemented |
LE0214 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,259 | $2,300 | Implemented |