Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0400 # 02 Y:2015 | 02 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,648 | $512 | Implemented |
LE0400 # 16 Y:2015 | 16 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,312 | $35,000 | Implemented |
LE0400 # 15 Y:2015 | 15 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,678 | $6,940 | Implemented |
LE0400 # 14 Y:2015 | 14 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $5,902 | $24,000 | Implemented |
LE0400 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,886 | $69,160 | Implemented |
LE0400 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,188 | $5,469 | Implemented |
LE0400 # 11 Y:2015 | 11 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $42,371 | $95,000 | Not Implemented |
LE0400 # 10 Y:2015 | 10 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,729 | $48,067 | Implemented |
LE0400 # 08 Y:2015 | 08 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,074 | $35,000 | Not Implemented |
LE0400 # 07 Y:2015 | 07 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,457 | $3,025 | Implemented |
LE0400 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $27,922 | $10,500 | Not Implemented |
LE0400 # 05 Y:2015 | 05 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $30,027 | $5,000 | Not Implemented |
LE0400 # 04 Y:2015 | 04 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $8,953 | $1,920 | Not Implemented |
LE0400 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,673 | $1,000 | Implemented |
LE0400 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $16,723 | $28 | Implemented |
LE0400 # 09 Y:2015 | 09 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,334 | $16,500 | Implemented |
DL0044 # 02 Y:2009 | 02 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $31,002 | $5,550 | Not Implemented |
DL0044 # 06 Y:2009 | 06 | 2009 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $37,189 | $70,000 | Not Implemented |
DL0044 # 05 Y:2009 | 05 | 2009 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $6,452 | $0 | Not Implemented |
DL0044 # 04 Y:2009 | 04 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,400 | $950 | Not Implemented |
DL0044 # 03 Y:2009 | 03 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,300 | $575 | Not Implemented |
DL0044 # 01 Y:2009 | 01 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $89,460 | $41,150 | Not Implemented |
RU0047 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,097 | $9,000 | Not Implemented |
RU0047 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,029 | $0 | Implemented |
RU0047 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,402 | $441 | Implemented |