Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0334 # 02 Y:2007 | 02 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $210,390 | $615,001 | Not Implemented |
BD0334 # 01 Y:2007 | 01 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $242,313 | $111,001 | Implemented |
BD0334 # 08 Y:2007 | 08 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,625 | $24,551 | Implemented |
BD0334 # 07 Y:2007 | 07 | 2007 | USE SYNTHETIC LUBRICANT | $3,966 | $301 | Implemented |
BD0334 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $910 | $2 | Not Implemented |
BD0334 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $3,999 | $1,576 | Implemented |
BD0334 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,532 | $3,690 | Implemented |
BD0334 # 03 Y:2007 | 03 | 2007 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $55,549 | $2,097 | Not Implemented |
UD0766 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $78,420 | $279,770 | Implemented |
UD0766 # 07 Y:2007 | 07 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $40,000 | $1,100 | Implemented |
UD0766 # 06 Y:2007 | 06 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $57,000 | $30,000 | Not Implemented |
UD0766 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $832,000 | $400,000 | Not Implemented |
UD0766 # 04 Y:2007 | 04 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $164,851 | $140,000 | Not Implemented |
UD0766 # 03 Y:2007 | 03 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $306,000 | $20,000 | Not Implemented |
UD0766 # 02 Y:2007 | 02 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $942,000 | $520,000 | Not Implemented |
UD0766 # 08 Y:2007 | 08 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,800 | $20,000 | Implemented |
UD0766 # 13 Y:2007 | 13 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,806 | $6,000 | Not Implemented |
UD0766 # 09 Y:2007 | 09 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $26,203 | $10,000 | Not Implemented |
UD0766 # 11 Y:2007 | 11 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,564 | $19,275 | Implemented |
UD0766 # 12 Y:2007 | 12 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,135 | $0 | Not Implemented |
UD0766 # 15 Y:2007 | 15 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,068 | $2,130 | Not Implemented |
UD0766 # 16 Y:2007 | 16 | 2007 | INSTALL OCCUPANCY SENSORS | $1,641 | $6,210 | Not Implemented |
UD0766 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,343 | $85,140 | Implemented |
UD0766 # 14 Y:2007 | 14 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,115 | $0 | Implemented |
MA0620 # 05 Y:2007 | 05 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $9,514 | $1,776 | Implemented |