Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

768

matching recommendations
Reset
SIC 3354 Aluminum Extruded Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0815 # 09 Y:2005 09 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,456 $39,000 Implemented
WV0318 # 01 Y:2005 01 2005 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $39,332 $8,388 Implemented
WV0318 # 02 Y:2005 02 2005 RECOVER WASTE HEAT FROM EQUIPMENT $21,012 $3,064 Implemented
WV0318 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,845 $6,470 Implemented
WV0318 # 04 Y:2005 04 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $12,757 $620 Implemented
WV0318 # 05 Y:2005 05 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,670 $587 Implemented
WV0318 # 06 Y:2005 06 2005 COVER OPEN TANKS $5,974 $12,120 Not Implemented
WV0318 # 07 Y:2005 07 2005 DEVELOP A REPAIR/REPLACE POLICY $4,198 $330 Implemented
WV0318 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,582 $11,537 Not Implemented
WV0318 # 09 Y:2005 09 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,258 $360 Implemented
WV0318 # 10 Y:2005 10 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,532 $5,220 Implemented
AM0477 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $20,415 $400 Implemented
AM0477 # 02 Y:2005 02 2005 INSULATE BARE EQUIPMENT $4,060 $485 Not Implemented
AM0477 # 03 Y:2005 03 2005 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $6,062 $0 Implemented
AM0477 # 04 Y:2005 04 2005 INSTALL SKYLIGHTS $5,600 $15,600 Not Implemented
AM0477 # 05 Y:2005 05 2005 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $5,200 $4,300 Not Implemented
AM0477 # 06 Y:2005 06 2005 COMBINE UTILITY METERS $118 $0 Implemented
AS0383 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $842 $200 Not Implemented
AS0383 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $21,498 $120 Not Implemented
AS0383 # 03 Y:2004 03 2004 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $16,320 $40,000 Not Implemented
AS0383 # 04 Y:2004 04 2004 INSTALL OCCUPANCY SENSORS $2,878 $1,350 Not Implemented
AS0383 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,064 $12,003 Not Implemented
AS0383 # 06 Y:2004 06 2004 COVER OPEN TANKS $4,988 $6,000 Not Implemented
AS0383 # 07 Y:2004 07 2004 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $244 $600 Not Implemented
AS0383 # 08 Y:2004 08 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,942 $600 Not Implemented