Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
768
matching recommendationsSIC | 3354 | Aluminum Extruded Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0330 # 08 Y:1998 | 08 | 1998 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,260 | $40 | Implemented |
AM0330 # 09 Y:1998 | 09 | 1998 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $814 | $1,120 | Not Implemented |
AM0330 # 10 Y:1998 | 10 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $420 | $0 | Implemented |
AM0330 # 11 Y:1998 | 11 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $405 | $0 | Implemented |
AM0330 # 12 Y:1998 | 12 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $340 | $20 | Implemented |
AM0330 # 13 Y:1998 | 13 | 1998 | USE SYNTHETIC LUBRICANT | $275 | $0 | Implemented |
AM0330 # 14 Y:1998 | 14 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $239 | $745 | Implemented |
AM0330 # 15 Y:1998 | 15 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $170 | $0 | Implemented |
OK0517 # 01 Y:1997 | 01 | 1997 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $124,800 | $150,000 | Implemented |
OK0517 # 02 Y:1997 | 02 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $15,653 | $36,725 | Implemented |
OK0517 # 03 Y:1997 | 03 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,810 | $5,000 | Not Implemented |
OK0517 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $434 | $1,872 | Implemented |
OK0517 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45 | $40 | Implemented |
SD0162 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,580 | $53,210 | Implemented |
SD0162 # 02 Y:1997 | 02 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $242,027 | $70,000 | Not Implemented |
SD0162 # 03 Y:1997 | 03 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $198,103 | $70,000 | Not Implemented |
SD0162 # 04 Y:1997 | 04 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $155,879 | $298,500 | Not Implemented |
SD0162 # 05 Y:1997 | 05 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,408 | $6,200 | Implemented |
SD0162 # 06 Y:1997 | 06 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,971 | $2,200 | Implemented |
SD0162 # 07 Y:1997 | 07 | 1997 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,597 | $3,500 | Implemented |
SD0162 # 08 Y:1997 | 08 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,744 | $150 | Implemented |
SD0162 # 09 Y:1997 | 09 | 1997 | INSTALL OCCUPANCY SENSORS | $866 | $1,394 | Implemented |
SD0162 # 10 Y:1997 | 10 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $33,421 | $31,250 | Implemented |
SD0162 # 11 Y:1997 | 11 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $7,430 | $500 | Implemented |
SD0162 # 12 Y:1997 | 12 | 1997 | USE AUTOMATIC CLEANING EQUIPMENT | $50,117 | $40,000 | Not Implemented |