IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,412

matching recommendations
Reset
SIC 336 Nonferrous Foundries (castings)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0320 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,978 $5,805 Implemented
WV0320 # 03 Y:2005 03 2005 BURN WASTE OIL FOR HEAT $4,770 $4,000 Not Implemented
WV0320 # 04 Y:2005 04 2005 INSTALL OCCUPANCY SENSORS $4,359 $4,750 Implemented
WV0320 # 05 Y:2005 05 2005 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,094 $2,700 Implemented
WV0320 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,232 $0 Not Implemented
WV0320 # 07 Y:2005 07 2005 USE COMPRESSOR AIR FILTERS $2,183 $800 Not Implemented
WV0320 # 08 Y:2005 08 2005 RECOVER WASTE HEAT FROM EQUIPMENT $1,732 $1,645 Implemented
WV0320 # 09 Y:2005 09 2005 DEVELOP A REPAIR/REPLACE POLICY $1,621 $213 Implemented
WV0320 # 10 Y:2005 10 2005 PREHEAT COMBUSTION AIR WITH WASTE HEAT $975 $955 Not Implemented
WV0320 # 11 Y:2005 11 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $728 $667 Implemented
WV0320 # 12 Y:2005 12 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $487 $400 Not Implemented
WV0320 # 13 Y:2005 13 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $474 $488 Not Implemented
WV0320 # 14 Y:2005 14 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $457 $430 Implemented
WV0320 # 15 Y:2005 15 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $438 $80 Implemented
WV0320 # 16 Y:2005 16 2005 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $351 $26 Not Implemented
WI0493 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,163 $49,680 Not Implemented
WI0493 # 02 Y:2005 02 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $26,534 $11,200 Not Implemented
WI0493 # 03 Y:2005 03 2005 CONTRACT A WOOD PALLET RECYCLING COMPANY $22,020 $0 Not Implemented
WI0493 # 04 Y:2005 04 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $12,731 $1,920 Not Implemented
WI0493 # 05 Y:2005 05 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,287 $1,300 Not Implemented
WI0493 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,969 $2,000 Not Implemented
LM0085 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,324 $205 Implemented
LM0085 # 02 Y:2004 02 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $167 $0 Implemented
LM0085 # 03 Y:2004 03 2004 CLEAN FOULING FROM WATER LINES REGULARLY $2,852 $180 Implemented
LM0085 # 04 Y:2004 04 2004 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,335 $741 Not Implemented