Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,394
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0163 # 15 Y:1985 | 15 | 1985 | IMPROVE LUBRICATION PRACTICES | $1,119 | $1,016 | Not Implemented |
KU0163 # 16 Y:1985 | 16 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $2,273 | $1,000 | Implemented |
KU0163 # 17 Y:1985 | 17 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $363 | $900 | Implemented |
KU0163 # 18 Y:1985 | 18 | 1985 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $160 | $0 | Implemented |
KU0163 # 19 Y:1985 | 19 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11 | $0 | Not Implemented |
KU0163 # 20 Y:1985 | 20 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,287 | $2,874 | Not Implemented |
MA0023 # 01 Y:1985 | 01 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,752 | $4,628 | Implemented |
MA0023 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $225 | $100 | Implemented |
MA0023 # 03 Y:1985 | 03 | 1985 | REVISE SMOKE CLEANUP FROM OPERATIONS | $6,061 | $1,447 | Implemented |
MA0023 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $450 | $66 | Implemented |
LT0001 # 01 Y:1984 | 01 | 1984 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $6,220 | $12,200 | Implemented |
LT0001 # 02 Y:1984 | 02 | 1984 | ADJUST VENTS TO MINIMIZE ENERGY USE | $10,250 | $900 | Not Implemented |
LT0001 # 03 Y:1984 | 03 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,340 | $0 | Implemented |
LT0001 # 04 Y:1984 | 04 | 1984 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,420 | $0 | Not Implemented |
LT0001 # 05 Y:1984 | 05 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $66,754 | $0 | Implemented |
TN0207 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $25,155 | $12,500 | Implemented |
TN0207 # 02 Y:1984 | 02 | 1984 | INSULATE BARE EQUIPMENT | $18,357 | $750 | Implemented |
TN0207 # 03 Y:1984 | 03 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,215 | $21,000 | Implemented |
TN0207 # 04 Y:1984 | 04 | 1984 | INSTALL SET-BACK TIMERS | $645 | $0 | Implemented |
TN0207 # 05 Y:1984 | 05 | 1984 | INSULATE BARE EQUIPMENT | $250 | $78 | Not Implemented |
UD0069 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,154 | $272 | Not Implemented |
UD0069 # 02 Y:1982 | 02 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $257 | $500 | Not Implemented |
UD0069 # 03 Y:1982 | 03 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,195 | $3,000 | Not Implemented |
UD0069 # 04 Y:1982 | 04 | 1982 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $2,157 | $2,629 | Not Implemented |
UD0070 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $594 | $158 | Not Implemented |