Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0058 # 08 Y:1989 | 08 | 1989 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $847 | $1,170 | Implemented |
OR0058 # 07 Y:1989 | 07 | 1989 | COVER OPEN TANKS | $1,428 | $0 | Implemented |
OR0058 # 06 Y:1989 | 06 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $283 | $172 | Not Implemented |
OR0058 # 05 Y:1989 | 05 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $519 | $250 | Not Implemented |
MA0154 # 01 Y:1989 | 01 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,565 | $12,000 | Implemented |
MA0154 # 02 Y:1989 | 02 | 1989 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $882 | $2,892 | Implemented |
MA0154 # 03 Y:1989 | 03 | 1989 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,186 | $4,403 | Not Implemented |
MA0154 # 04 Y:1989 | 04 | 1989 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $24,986 | $4,440 | Not Implemented |
MA0154 # 05 Y:1989 | 05 | 1989 | INSULATE BARE EQUIPMENT | $395 | $757 | Not Implemented |
MA0154 # 06 Y:1989 | 06 | 1989 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,999 | $8,160 | Not Implemented |
OR0058 # 01 Y:1989 | 01 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,281 | $0 | Implemented |
OR0058 # 02 Y:1989 | 02 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,976 | $200 | Implemented |
OR0058 # 03 Y:1989 | 03 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,940 | $200 | Not Implemented |
OR0058 # 04 Y:1989 | 04 | 1989 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,914 | $200 | Implemented |
KU0276 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $658 | $150 | Implemented |
KU0276 # 05 Y:1989 | 05 | 1989 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $460 | $400 | Not Implemented |
KU0276 # 04 Y:1989 | 04 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,066 | $22,000 | Not Implemented |
KU0276 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $243 | $133 | Implemented |
KU0276 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $757 | $1,432 | Not Implemented |
WI0053 # 04 Y:1989 | 04 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $577 | $500 | Implemented |
WI0053 # 03 Y:1989 | 03 | 1989 | INSTALL STORM WINDOWS AND DOORS | $2,689 | $6,820 | Implemented |
WI0053 # 02 Y:1989 | 02 | 1989 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $12,776 | $15,000 | Implemented |
WI0053 # 06 Y:1989 | 06 | 1989 | IMPROVE LUBRICATION PRACTICES | $6,226 | $0 | Not Implemented |
WI0053 # 05 Y:1989 | 05 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $487 | $1,000 | Implemented |
WI0053 # 01 Y:1989 | 01 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $68,209 | $80,000 | Implemented |