Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

154

matching recommendations
Reset
SIC 3363 Aluminum Die-castings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0761 # 02 Y:2007 02 2007 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $26,967 $130,000 Implemented
UD0761 # 03 Y:2007 03 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $18,895 $660 Implemented
UD0761 # 04 Y:2007 04 2007 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $15,090 $93,600 Implemented
UD0761 # 05 Y:2007 05 2007 COVER OPEN TANKS $12,478 $1,243 Not Implemented
UD0761 # 06 Y:2007 06 2007 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $4,701 $4,500 Not Implemented
UD0761 # 07 Y:2007 07 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,079 $11,000 Implemented
UD0761 # 08 Y:2007 08 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,582 $2,000 Implemented
UD0761 # 13 Y:2007 13 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $357 $0 Implemented
UD0761 # 11 Y:2007 11 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,025 $0 Implemented
UD0761 # 09 Y:2007 09 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,368 $0 Implemented
UD0742 # 14 Y:2006 14 2006 UPGRADE CONTROLS ON COMPRESSORS $17,949 $0 Implemented
UD0742 # 16 Y:2006 16 2006 REDUCE WATER USE WITH COUNTER CURRENT RINSING $7,083 $0 Implemented
UD0742 # 17 Y:2006 17 2006 USE OPTIMUM THICKNESS INSULATION $4,031 $9,057 Not Implemented
UD0742 # 18 Y:2006 18 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,020 $0 Implemented
UD0742 # 19 Y:2006 19 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $874 $867 Implemented
UD0742 # 12 Y:2006 12 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $19,230 $0 Implemented
UD0742 # 11 Y:2006 11 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,660 $122,500 Implemented
UD0742 # 07 Y:2006 07 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $67,853 $0 Not Implemented
UD0742 # 06 Y:2006 06 2006 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $141,723 $50,000 Not Implemented
UD0742 # 05 Y:2006 05 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $157,269 $50,000 Not Implemented
UD0742 # 04 Y:2006 04 2006 REDESIGN PROCESS $174,377 $0 Implemented
UD0742 # 03 Y:2006 03 2006 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $185,439 $0 Not Implemented
UD0742 # 02 Y:2006 02 2006 UPGRADE CONTROLS ON COMPRESSORS $198,228 $100,000 Implemented
UD0742 # 01 Y:2006 01 2006 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $314,266 $2,000,000 Not Implemented
UD0742 # 13 Y:2006 13 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $18,813 $51,160 Not Implemented