Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

99

matching recommendations
Reset
SIC 3363 Aluminum Die-castings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0357 # 11 Y:1999 11 1999 INSULATE BARE EQUIPMENT $494 $848 Not Implemented
WI0357 # 06 Y:1999 06 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $900 $210 Implemented
WI0357 # 07 Y:1999 07 1999 DISTILL CONTAMINATED SOLVENTS FOR REUSE $2,963 $7,000 Not Implemented
WI0357 # 08 Y:1999 08 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,702 $1,000 Not Implemented
WI0357 # 09 Y:1999 09 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,780 $0 Not Implemented
WI0357 # 10 Y:1999 10 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,131 $4,017 Implemented
BD0004 # 01 Y:1994 01 1994 USE POWER DURING OFF-PEAK PERIODS $3,162 $1,000 Implemented
BD0004 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,364 $10,034 Implemented
BD0004 # 03 Y:1994 03 1994 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $7,352 $250 Implemented
BD0004 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $537 $1,800 Not Implemented
WI0184 # 03 Y:1993 03 1993 INSTALL OCCUPANCY SENSORS $1,425 $225 Implemented
WI0184 # 01 Y:1993 01 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,627 $8,250 Not Implemented
WI0184 # 08 Y:1993 08 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $162 $0 Not Implemented
WI0184 # 07 Y:1993 07 1993 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $637 $225 Not Implemented
WI0184 # 06 Y:1993 06 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,030 $640 Not Implemented
WI0184 # 05 Y:1993 05 1993 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,440 $2,800 Implemented
WI0184 # 04 Y:1993 04 1993 INSULATE BARE EQUIPMENT $4,490 $926 Not Implemented
WI0184 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,777 $3,952 Implemented
WI0084 # 06 Y:1990 06 1990 INSTALL TIMERS AND/OR THERMOSTATS $478 $250 Implemented
WI0084 # 05 Y:1990 05 1990 INSTALL SET-BACK TIMERS $730 $600 Not Implemented
WI0084 # 04 Y:1990 04 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $930 $2,000 Implemented
WI0084 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $705 $1,328 Implemented
WI0084 # 02 Y:1990 02 1990 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,910 $2,000 Implemented
WI0084 # 01 Y:1990 01 1990 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $23,340 $0 Not Implemented