Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

28

matching recommendations
Reset
SIC 3366 Copper Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0916 # 02 Y:2014 02 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,027 $0 Not Implemented
UD0916 # 01 Y:2014 01 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $5,270 $0 Not Implemented
UD0916 # 12 Y:2014 12 2014 CONTRACT A WOOD PALLET RECYCLING COMPANY $12,800 $0 Implemented
UD0916 # 11 Y:2014 11 2014 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $9,661 $40,000 Not Implemented
UD0916 # 10 Y:2014 10 2014 UPGRADE CONTROLS ON COMPRESSORS $10,562 $110,000 Implemented
UD0916 # 09 Y:2014 09 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,978 $1,000 Implemented
UD0916 # 08 Y:2014 08 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $896 $0 Not Implemented
UD0916 # 07 Y:2014 07 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,426 $4,150 Not Implemented
UD0916 # 06 Y:2014 06 2014 INSTALL OCCUPANCY SENSORS $503 $500 Implemented
UD0916 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,413 $26,040 Not Implemented
UD0916 # 04 Y:2014 04 2014 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $25,351 $43,280 Not Implemented
UD0916 # 03 Y:2014 03 2014 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $6,076 $11,700 Not Implemented
WV0320 # 16 Y:2005 16 2005 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $351 $26 Not Implemented
WV0320 # 15 Y:2005 15 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $438 $80 Implemented
WV0320 # 14 Y:2005 14 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $457 $430 Implemented
WV0320 # 13 Y:2005 13 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $474 $488 Not Implemented
WV0320 # 12 Y:2005 12 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $487 $400 Not Implemented
WV0320 # 11 Y:2005 11 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $728 $667 Implemented
WV0320 # 10 Y:2005 10 2005 PREHEAT COMBUSTION AIR WITH WASTE HEAT $975 $955 Not Implemented
WV0320 # 09 Y:2005 09 2005 DEVELOP A REPAIR/REPLACE POLICY $1,621 $213 Implemented
WV0320 # 08 Y:2005 08 2005 RECOVER WASTE HEAT FROM EQUIPMENT $1,732 $1,645 Implemented
WV0320 # 07 Y:2005 07 2005 USE COMPRESSOR AIR FILTERS $2,183 $800 Not Implemented
WV0320 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,232 $0 Not Implemented
WV0320 # 05 Y:2005 05 2005 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,094 $2,700 Implemented
WV0320 # 04 Y:2005 04 2005 INSTALL OCCUPANCY SENSORS $4,359 $4,750 Implemented