Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22

matching recommendations
Reset
SIC 3369 Nonferrous Foundries, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0392 # 05 Y:1997 05 1997 CONVERT TO AQUEOUS CLEANING $276 $759 Implemented
MA0392 # 04 Y:1997 04 1997 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $320 $268 Implemented
MA0392 # 03 Y:1997 03 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,388 $6,000 Not Implemented
MA0392 # 02 Y:1997 02 1997 $8,500 $3,000 Not Implemented
MA0392 # 01 Y:1997 01 1997 $34,500 $21,950 Implemented
MA0325 # 05 Y:1995 05 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $922 $0 Implemented
MA0325 # 10 Y:1995 10 1995 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $7,953 $5,526 Implemented
MA0325 # 09 Y:1995 09 1995 RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE $28,487 $53,330 Implemented
MA0325 # 08 Y:1995 08 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $378 $255 Implemented
MA0325 # 07 Y:1995 07 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $382 $0 Implemented
MA0325 # 06 Y:1995 06 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $453 $1,190 Implemented
MA0325 # 04 Y:1995 04 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,557 $1,000 Implemented
MA0325 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,545 $2,500 Not Implemented
MA0325 # 02 Y:1995 02 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,067 $4,632 Not Implemented
MA0325 # 01 Y:1995 01 1995 COVER OPEN TANKS $3,618 $1,883 Implemented
MA0056 # 01 Y:1986 01 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,510 $2,500 Implemented
MA0056 # 07 Y:1986 07 1986 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $6,965 $0 Not Implemented
MA0056 # 06 Y:1986 06 1986 INSTALL STORM WINDOWS AND DOORS $1,206 $1,760 Not Implemented
MA0056 # 05 Y:1986 05 1986 INSTALL TIMERS AND/OR THERMOSTATS $2,380 $1,200 Implemented
MA0056 # 04 Y:1986 04 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $566 $109 Not Implemented
MA0056 # 03 Y:1986 03 1986 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,812 $1,700 Implemented
MA0056 # 02 Y:1986 02 1986 COVER OPEN TANKS $157 $0 Implemented