Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
587
matching recommendationsSIC | 3398 | Metal Heat Treating |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0227 # 01 Y:1987 | 01 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $26,035 | $30,000 | Implemented |
UD0227 # 02 Y:1987 | 02 | 1987 | OPTIMIZE PLANT POWER FACTOR | $4,712 | $12,000 | Implemented |
UD0227 # 03 Y:1987 | 03 | 1987 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,245 | $0 | Not Implemented |
UD0227 # 04 Y:1987 | 04 | 1987 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $534 | $6,000 | Implemented |
UD0227 # 05 Y:1987 | 05 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,752 | $0 | Not Implemented |
AT0045 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,281 | $4,444 | Implemented |
AT0045 # 02 Y:1986 | 02 | 1986 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $12,817 | $2,000 | Not Implemented |
AT0045 # 03 Y:1986 | 03 | 1986 | INSULATE BARE EQUIPMENT | $2,194 | $100 | Implemented |
AT0045 # 04 Y:1986 | 04 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $78,041 | $50,000 | Implemented |
AT0045 # 05 Y:1986 | 05 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,209 | $5,000 | Implemented |
AT0045 # 06 Y:1986 | 06 | 1986 | AIR CONDITION ONLY SPACE NECESSARY | $724 | $2,000 | Implemented |
OK0201 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $361 | $39 | Implemented |
OK0201 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $564 | $0 | Implemented |
OK0201 # 03 Y:1986 | 03 | 1986 | USE RADIANT HEATER FOR SPOT HEATING | $7,928 | $18,000 | Not Implemented |
OK0201 # 04 Y:1986 | 04 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $74 | $50 | Implemented |
OK0201 # 05 Y:1986 | 05 | 1986 | COVER OPEN TANKS | $88 | $133 | Not Implemented |
ST0060 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $862 | $193 | Not Implemented |
ST0060 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,538 | $70 | Not Implemented |
ST0060 # 03 Y:1986 | 03 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,813 | $821 | Not Implemented |
ST0060 # 04 Y:1986 | 04 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $32,041 | $30,000 | Not Implemented |
ST0060 # 05 Y:1986 | 05 | 1986 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $134,226 | $93,000 | Implemented |
OK0136 # 01 Y:1984 | 01 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $124 | $0 | Implemented |
OK0136 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33 | $92 | Implemented |
OK0136 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $80 | $43 | Implemented |
OK0136 # 04 Y:1984 | 04 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $163 | $165 | Not Implemented |