Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21

matching recommendations
Reset
SIC 3399 Primary Metal Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0392 # 08 Y:2009 08 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $186 $577 Implemented
NC0392 # 07 Y:2009 07 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,657 $33,097 Implemented
NC0392 # 06 Y:2009 06 2009 DEVELOP A REPAIR/REPLACE POLICY $2,139 $3,888 Not Implemented
NC0392 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $315 $100 Implemented
NC0392 # 04 Y:2009 04 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,938 $4,825 Not Implemented
NC0392 # 03 Y:2009 03 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,152 $23,000 Not Implemented
NC0392 # 02 Y:2009 02 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $74,466 $220,000 Not Implemented
NC0392 # 01 Y:2009 01 2009 INSTALL EQUIPMENT TO MOVE PRODUCT $21,004 $50,000 Implemented
NC0303 # 05 Y:2004 05 2004 REDESIGN PROCESS $73,700 $35,000 Not Implemented
NC0303 # 07 Y:2004 07 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,085 $1,385 Not Implemented
NC0303 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,224 $100 Implemented
NC0303 # 04 Y:2004 04 2004 REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE $11,844 $18,280 Not Implemented
NC0303 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $18,426 $18,825 Not Implemented
NC0303 # 02 Y:2004 02 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $20,788 $0 Not Implemented
NC0303 # 01 Y:2004 01 2004 ADOPT IN-HOUSE MATERIAL GENERATION $34,730 $120,000 Not Implemented
NC0002 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $566 $522 Implemented
NC0002 # 06 Y:1993 06 1993 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $17,784 $39,880 Not Implemented
NC0002 # 05 Y:1993 05 1993 INSTALL SKYLIGHTS $5,957 $9,715 Not Implemented
NC0002 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,206 $100 Implemented
NC0002 # 03 Y:1993 03 1993 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,991 $1,209 Implemented
NC0002 # 02 Y:1993 02 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $3,351 $120 Not Implemented