Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
525
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0206 # 07 Y:1997 | 07 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,760 | $0 | Not Implemented |
AS0206 # 08 Y:1997 | 08 | 1997 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $12,000 | $100 | Not Implemented |
AS0193 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $34,527 | $45,000 | Implemented |
AS0193 # 02 Y:1996 | 02 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,963 | $7,000 | Implemented |
AS0193 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $24,827 | $17,598 | Implemented |
AS0193 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,838 | $0 | Implemented |
AS0193 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,599 | $25,001 | Implemented |
AS0193 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,904 | $6,140 | Not Implemented |
AS0193 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $881 | $450 | Implemented |
AS0193 # 08 Y:1996 | 08 | 1996 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $24,214 | $900 | Implemented |
AS0188 # 01 Y:1996 | 01 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $11,373 | $21,500 | Implemented |
AS0188 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,900 | $13,282 | Implemented |
AS0188 # 03 Y:1996 | 03 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,208 | $7,500 | Not Implemented |
AS0188 # 04 Y:1996 | 04 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,409 | $9,450 | Implemented |
AS0188 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,780 | $17,184 | Implemented |
AS0188 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $2,399 | $2,100 | Not Implemented |
AS0188 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $280 | $450 | Implemented |
AS0173 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,273 | $7,461 | Implemented |
AS0173 # 02 Y:1996 | 02 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,195 | $0 | Implemented |
AS0173 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,158 | $0 | Not Implemented |
AS0173 # 04 Y:1996 | 04 | 1996 | USE SYNTHETIC LUBRICANT | $1,077 | $2,860 | Not Implemented |
AS0173 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $951 | $4,788 | Not Implemented |
AS0173 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $616 | $450 | Not Implemented |
AS0173 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $148 | $270 | Not Implemented |
AS0173 # 08 Y:1996 | 08 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $3,429 | $4,000 | Not Implemented |