Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
595
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0434 # 01 Y:2002 | 01 | 2002 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $133,384 | $140,000 | Not Implemented |
WI0434 # 02 Y:2002 | 02 | 2002 | INSTALL OCCUPANCY SENSORS | $9,841 | $25,000 | Not Implemented |
WI0434 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $5,168 | $11,700 | Implemented |
WI0434 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,746 | $12,600 | Not Implemented |
WI0434 # 05 Y:2002 | 05 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,556 | $740 | Implemented |
WI0434 # 06 Y:2002 | 06 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,280 | $2,832 | Not Implemented |
WI0434 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,191 | $588 | Implemented |
WI0429 # 01 Y:2002 | 01 | 2002 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $49,518 | $23,000 | Not Implemented |
WI0429 # 02 Y:2002 | 02 | 2002 | INSTALL OCCUPANCY SENSORS | $11,200 | $25,000 | Not Implemented |
WI0429 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $3,559 | $2,900 | Not Implemented |
WI0429 # 04 Y:2002 | 04 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,146 | $1,280 | Not Implemented |
WI0429 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $514 | $150 | Implemented |
WI0418 # 01 Y:2002 | 01 | 2002 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $151,650 | $60,000 | Not Implemented |
WI0418 # 02 Y:2002 | 02 | 2002 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $104,205 | $715,000 | n/a |
WI0418 # 03 Y:2002 | 03 | 2002 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $65,100 | $150,000 | n/a |
WI0418 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,681 | $8,775 | Not Implemented |
WI0418 # 05 Y:2002 | 05 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,487 | $15,000 | n/a |
WI0418 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $870 | $150 | Implemented |
WI0418 # 07 Y:2002 | 07 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $850 | $0 | Not Implemented |
WI0418 # 08 Y:2002 | 08 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,492 | $630 | Not Implemented |
WI0414 # 01 Y:2002 | 01 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,469 | $1,800 | Not Implemented |
WI0414 # 02 Y:2002 | 02 | 2002 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,619 | $14,000 | Not Implemented |
WI0414 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,225 | $0 | Implemented |
WI0414 # 04 Y:2002 | 04 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,730 | $0 | Implemented |
WI0414 # 05 Y:2002 | 05 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,560 | $1,033 | Not Implemented |