IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,208

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IP0027 # 06 Y:2014 06 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,988 $280 Not Implemented
IP0027 # 07 Y:2014 07 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $5,453 $671 Not Implemented
IP0027 # 08 Y:2014 08 2014 REUSE / RECYCLE/ SELL PAPER PRODUCTS $72,576 $12,435 Not Implemented
IP0027 # 09 Y:2014 09 2014 INSTALL TIMERS AND/OR THERMOSTATS $3,685 $3,528 Not Implemented
IP0027 # 10 Y:2014 10 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,185 $85,493 Not Implemented
IP0026 # 01 Y:2014 01 2014 APPLY FOR INVESTMENT INCENTIVES $6,604 $0 Not Implemented
IP0026 # 02 Y:2014 02 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,247 $70 Not Implemented
IP0026 # 03 Y:2014 03 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,175 $67 Not Implemented
IP0026 # 04 Y:2014 04 2014 REPLACE BOILER $47,742 $25,000 Not Implemented
IP0026 # 05 Y:2014 05 2014 INSULATE BARE EQUIPMENT $320 $300 Not Implemented
IP0026 # 06 Y:2014 06 2014 INSULATE BARE EQUIPMENT $221 $286 Not Implemented
IP0026 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $553 $991 Not Implemented
IP0026 # 08 Y:2014 08 2014 OPTIMIZE PLANT POWER FACTOR $5,683 $16,847 Not Implemented
AM0661 # 01 Y:2014 01 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $4,760 $0 Implemented
AM0661 # 02 Y:2014 02 2014 OPTIMIZE PLANT POWER FACTOR $3,420 $10,310 Not Implemented
AM0661 # 03 Y:2014 03 2014 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,170 $0 Implemented
AM0661 # 04 Y:2014 04 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,440 $1,500 Implemented
AM0661 # 05 Y:2014 05 2014 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $865 $3,995 Implemented
AM0661 # 06 Y:2014 06 2014 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $560 $845 Implemented
AM0661 # 07 Y:2014 07 2014 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $540 $0 Implemented
AM0661 # 08 Y:2014 08 2014 USE SYNTHETIC LUBRICANT $500 $0 Not Implemented
AM0661 # 09 Y:2014 09 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $360 $280 Implemented
AM0661 # 10 Y:2014 10 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $312 $180 Implemented
NC0514 # 01 Y:2014 01 2014 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $23,503 $100 Implemented
NC0514 # 02 Y:2014 02 2014 RECOVER WASTE HEAT FROM EQUIPMENT $13,824 $50,000 Not Implemented