Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,620
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0694 # 06 Y:2004 | 06 | 2004 | REDUCE VENTILATION AIR | $18,999 | $0 | Implemented |
UD0694 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,530 | $5,780 | Implemented |
UD0694 # 08 Y:2004 | 08 | 2004 | USE CONTINUOUS EQUIPMENT WHICH RETAINS PROCESS HEATING CONVEYORS WITHIN THE HEATED CHAMBER | $4,207 | $3,323 | Not Implemented |
UD0694 # 09 Y:2004 | 09 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $3,140 | $0 | Not Implemented |
UD0694 # 10 Y:2004 | 10 | 2004 | INSTALL OCCUPANCY SENSORS | $1,427 | $210 | Implemented |
UD0694 # 11 Y:2004 | 11 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $883 | $1,962 | Implemented |
UD0694 # 12 Y:2004 | 12 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $860 | $845 | Not Implemented |
UD0694 # 13 Y:2004 | 13 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $790 | $660 | Implemented |
UD0694 # 14 Y:2004 | 14 | 2004 | DISCONNECT BALLASTS | $393 | $13 | Implemented |
UD0694 # 15 Y:2004 | 15 | 2004 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $288 | $0 | Implemented |
UD0693 # 13 Y:2004 | 13 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $506 | $0 | Implemented |
UD0693 # 14 Y:2004 | 14 | 2004 | DISCONNECT BALLASTS | $444 | $13 | Not Implemented |
UD0693 # 15 Y:2004 | 15 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $0 | Not Implemented |
UD0693 # 01 Y:2004 | 01 | 2004 | COVER OPEN TANKS | $110,615 | $44,621 | Not Implemented |
UD0693 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,110 | $16,200 | Not Implemented |
UD0693 # 03 Y:2004 | 03 | 2004 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $13,945 | $15,000 | Not Implemented |
UD0693 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,883 | $9,060 | Implemented |
UD0693 # 05 Y:2004 | 05 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,534 | $0 | Not Implemented |
UD0693 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,251 | $200 | Not Implemented |
UD0693 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,006 | $1,337 | Implemented |
UD0693 # 08 Y:2004 | 08 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,575 | $0 | Not Implemented |
UD0693 # 09 Y:2004 | 09 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,466 | $0 | Implemented |
UD0693 # 10 Y:2004 | 10 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $1,299 | $296 | Implemented |
UD0693 # 11 Y:2004 | 11 | 2004 | INSTALL OCCUPANCY SENSORS | $1,013 | $420 | Not Implemented |
UD0693 # 12 Y:2004 | 12 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $899 | $0 | Not Implemented |