IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,620

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0187 # 05 Y:2000 05 2000 USE SYNTHETIC LUBRICANT $1,056 $350 Implemented
WV0187 # 06 Y:2000 06 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $569 $300 Not Implemented
WV0187 # 07 Y:2000 07 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $815 $740 Implemented
WV0187 # 08 Y:2000 08 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,120 $1,350 Not Implemented
WV0187 # 09 Y:2000 09 2000 INSTALL SPECTRAL REFLECTORS / DELAMP $28,444 $15,958 Implemented
WV0187 # 10 Y:2000 10 2000 CONTRACT A WOOD PALLET RECYCLING COMPANY $252 $50 Implemented
WV0187 # 11 Y:2000 11 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $5,304 $75 Implemented
WV0187 # 12 Y:2000 12 2000 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $20,000 $7,000 Not Implemented
WV0187 # 13 Y:2000 13 2000 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $15,000 $1,200 Not Implemented
UM0149 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $836 $500 Implemented
UM0149 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $618 $200 Implemented
UM0149 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $2,322 $1,500 Not Implemented
UM0149 # 04 Y:1999 04 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,107 $10,500 Not Implemented
UM0149 # 05 Y:1999 05 1999 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $3,804 $0 Not Implemented
UM0149 # 06 Y:1999 06 1999 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $8,500 $40,000 Implemented
UM0149 # 07 Y:1999 07 1999 EXPAND OPERATIONS INTO UNUSED SPACE $357,000 $714,000 Not Implemented
UD0580 # 01 Y:1999 01 1999 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $862,392 $1,300,000 Not Implemented
UD0580 # 02 Y:1999 02 1999 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $134,400 $400,000 Not Implemented
UD0580 # 03 Y:1999 03 1999 RECOVER AND REUSE COOLING WATER $52,000 $140,000 Not Implemented
UD0580 # 04 Y:1999 04 1999 MOVE PRODUCT USING MECHANICAL MEANS $39,393 $10,000 Not Implemented
UD0580 # 05 Y:1999 05 1999 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $27,840 $3,500 Implemented
UD0580 # 06 Y:1999 06 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $27,804 $11,744 Implemented
UD0580 # 07 Y:1999 07 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,051 $30,337 Implemented
UD0580 # 08 Y:1999 08 1999 FILTER AND REUSE HYDRAULIC OIL $1,713 $2,500 Not Implemented
UD0580 # 09 Y:1999 09 1999 SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED $1,418 $0 Not Implemented