IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,750

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0334 # 11 Y:1998 11 1998 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $220 $0 Implemented
AM0333 # 01 Y:1998 01 1998 MODIFY STARTUP/SHUTDOWN TIMES $17,100 $0 Not Implemented
AM0333 # 02 Y:1998 02 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,300 $120 Implemented
AM0333 # 03 Y:1998 03 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $450 $0 Not Implemented
AM0333 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $290 $370 Not Implemented
AM0333 # 05 Y:1998 05 1998 PAY UTILITY BILLS ON TIME $100 $0 Implemented
AM0328 # 01 Y:1998 01 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $44,420 $0 Not Implemented
AM0328 # 02 Y:1998 02 1998 METER WASTE WATER $23,760 $27,000 Not Implemented
AM0328 # 03 Y:1998 03 1998 OPTIMIZE PLANT POWER FACTOR $11,750 $0 Implemented
AM0328 # 04 Y:1998 04 1998 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $3,940 $3,680 Not Implemented
AM0328 # 05 Y:1998 05 1998 USE SYNTHETIC LUBRICANT $1,635 $0 Not Implemented
AM0328 # 06 Y:1998 06 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $830 $0 Not Implemented
AM0328 # 07 Y:1998 07 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $500 $500 Implemented
AM0324 # 01 Y:1998 01 1998 OPTIMIZE PLANT POWER FACTOR $28,430 $104,000 Implemented
AM0324 # 02 Y:1998 02 1998 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $21,000 $500 Implemented
AM0324 # 03 Y:1998 03 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,800 $1,500 Implemented
AM0324 # 04 Y:1998 04 1998 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $1,840 $3,300 Not Implemented
AM0324 # 05 Y:1998 05 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,630 $0 Not Implemented
AM0324 # 06 Y:1998 06 1998 USE SYNTHETIC LUBRICANT $1,020 $0 Not Implemented
AM0324 # 07 Y:1998 07 1998 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $960 $0 Not Implemented
AM0324 # 08 Y:1998 08 1998 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $820 $0 Implemented
AM0324 # 09 Y:1998 09 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $590 $1,310 Implemented
AM0324 # 10 Y:1998 10 1998 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $150 $165 Implemented
AM0312 # 01 Y:1998 01 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $30,640 $1,200 Implemented
AM0312 # 02 Y:1998 02 1998 REPAIR AND ELIMINATE STEAM LEAKS $24,560 $5,000 Implemented