Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,620
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0247 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,332 | $1,500 | Implemented |
UD0247 # 05 Y:1988 | 05 | 1988 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $1,405 | $76 | Implemented |
UD0234 # 01 Y:1987 | 01 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,497 | $15,000 | Implemented |
UD0234 # 02 Y:1987 | 02 | 1987 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,021 | $0 | Implemented |
UD0234 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $200 | $60 | Implemented |
UD0232 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,451 | $0 | Not Implemented |
UD0232 # 02 Y:1987 | 02 | 1987 | INSULATE BARE EQUIPMENT | $3,368 | $795 | Implemented |
UD0232 # 03 Y:1987 | 03 | 1987 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,586 | $10,000 | Not Implemented |
UD0232 # 04 Y:1987 | 04 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,488 | $1,700 | Implemented |
UD0232 # 05 Y:1987 | 05 | 1987 | REDUCE GLAZED AREAS IN BUILDINGS | $3,241 | $8,860 | Not Implemented |
UD0224 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,584 | $0 | Not Implemented |
UD0224 # 02 Y:1987 | 02 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,048 | $7,200 | Not Implemented |
UD0224 # 03 Y:1987 | 03 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,509 | $6,000 | Not Implemented |
UD0224 # 04 Y:1987 | 04 | 1987 | REDUCE GLAZED AREAS IN BUILDINGS | $3,429 | $5,800 | Not Implemented |
UD0224 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,313 | $2,500 | Implemented |
UD0222 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $50,976 | $0 | Implemented |
UD0222 # 02 Y:1987 | 02 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,018 | $6,000 | Not Implemented |
UD0222 # 03 Y:1987 | 03 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,028 | $25,000 | Implemented |
UD0222 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,250 | $27,000 | Implemented |
UD0222 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,938 | $16,000 | Implemented |
UD0218 # 01 Y:1987 | 01 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $19,049 | $5,470 | Implemented |
UD0218 # 02 Y:1987 | 02 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,039 | $9,500 | Not Implemented |
UD0218 # 03 Y:1987 | 03 | 1987 | TURN OFF EQUIPMENT WHEN NOT IN USE | $463 | $129 | Not Implemented |
UD0218 # 04 Y:1987 | 04 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $11,481 | $0 | Implemented |
UD0209 # 01 Y:1986 | 01 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $4,634 | $3,000 | Implemented |