Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0009 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $262 | $800 | Implemented |
UM0009 # 04 Y:1994 | 04 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,513 | $1,500 | Not Implemented |
UM0009 # 05 Y:1994 | 05 | 1994 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $88,700 | $330,000 | Not Implemented |
UM0009 # 06 Y:1994 | 06 | 1994 | COVER OPEN TANKS | $4,163 | $2,440 | Implemented |
UM0009 # 07 Y:1994 | 07 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $760 | $932 | Not Implemented |
UM0009 # 08 Y:1994 | 08 | 1994 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,325 | $6,000 | Not Implemented |
UM0009 # 09 Y:1994 | 09 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $930 | $196 | Implemented |
UM0009 # 10 Y:1994 | 10 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,829 | $1,500 | Implemented |
UM0009 # 11 Y:1994 | 11 | 1994 | USE RADIANT HEATER FOR SPOT HEATING | $8,161 | $21,400 | Implemented |
ME0137 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $42,534 | $50,000 | Not Implemented |
ME0137 # 02 Y:1994 | 02 | 1994 | USE OPTIMUM THICKNESS INSULATION | $22,500 | $4,500 | Not Implemented |
ME0137 # 03 Y:1994 | 03 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $35,300 | $70,000 | Not Implemented |
ME0137 # 04 Y:1994 | 04 | 1994 | OPTIMIZE PLANT POWER FACTOR | $9,485 | $9,080 | Not Implemented |
ME0137 # 05 Y:1994 | 05 | 1994 | METER WASTE WATER | $18,700 | $1,350 | Not Implemented |
ME0137 # 06 Y:1994 | 06 | 1994 | REDUCE FLUID FLOW RATES | $1,088 | $1,010 | Not Implemented |
ME0137 # 07 Y:1994 | 07 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,915 | $30,000 | Not Implemented |
UD0435 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $7,057 | $10,000 | Implemented |
UD0435 # 02 Y:1994 | 02 | 1994 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,501 | $0 | Implemented |
UD0435 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,090 | $5,000 | Not Implemented |
UD0435 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,265 | $6,838 | Not Implemented |
UD0435 # 05 Y:1994 | 05 | 1994 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $28,851 | $50,000 | Not Implemented |
OR0209 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $732 | $750 | Not Implemented |
OR0209 # 02 Y:1994 | 02 | 1994 | IMPROVE COMBUSTION CONTROL CAPABILITY | $27,860 | $12,000 | Implemented |
OR0209 # 03 Y:1994 | 03 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $274 | $0 | Implemented |
OR0209 # 04 Y:1994 | 04 | 1994 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,640 | $2,670 | Implemented |