Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,760
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0076 # 03 Y:1990 | 03 | 1990 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,940 | $3,614 | Implemented |
AM0076 # 04 Y:1990 | 04 | 1990 | INSULATE BARE EQUIPMENT | $240 | $180 | Not Implemented |
AM0076 # 05 Y:1990 | 05 | 1990 | INSULATE BARE EQUIPMENT | $127 | $199 | Implemented |
AM0077 # 01 Y:1990 | 01 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,200 | $51,900 | Implemented |
AM0077 # 02 Y:1990 | 02 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,385 | $12,000 | Implemented |
AM0077 # 03 Y:1990 | 03 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,660 | $1,500 | Implemented |
AM0077 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $910 | $0 | Implemented |
AM0077 # 05 Y:1990 | 05 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $440 | $0 | Implemented |
AM0077 # 06 Y:1990 | 06 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34 | $31 | Implemented |
AM0079 # 01 Y:1990 | 01 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,390 | $2,000 | Implemented |
AM0079 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,990 | $26,637 | Implemented |
AM0079 # 03 Y:1990 | 03 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,440 | $2,000 | Implemented |
AM0079 # 04 Y:1990 | 04 | 1990 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,670 | $4,050 | Implemented |
AM0079 # 05 Y:1990 | 05 | 1990 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $470 | $0 | Implemented |
AM0079 # 06 Y:1990 | 06 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $340 | $0 | Implemented |
AM0079 # 07 Y:1990 | 07 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $255 | $90 | Implemented |
AM0079 # 08 Y:1990 | 08 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46 | $17 | Implemented |
AM0068 # 01 Y:1989 | 01 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $40,430 | $24,600 | Implemented |
AM0068 # 02 Y:1989 | 02 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,210 | $16,500 | Implemented |
AM0068 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $2,180 | $0 | Implemented |
AM0068 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $890 | $1,000 | Implemented |
AM0068 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $97 | Implemented |
AM0068 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $330 | $295 | Implemented |
AM0063 # 01 Y:1989 | 01 | 1989 | PAY UTILITY BILLS ON TIME | $1,269 | $0 | Implemented |
AM0063 # 02 Y:1989 | 02 | 1989 | INSTALL SET-BACK TIMERS | $1,250 | $160 | Implemented |