IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,208

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0162 # 02 Y:1993 02 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $16,677 $9,940 Not Implemented
ND0162 # 03 Y:1993 03 1993 INSTALL TIMERS AND/OR THERMOSTATS $8,311 $4,500 Implemented
ND0162 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,926 $500 Implemented
ND0162 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,324 $2,000 Not Implemented
ND0162 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,041 $1,171 Implemented
ND0162 # 07 Y:1993 07 1993 OPTIMIZE PLANT POWER FACTOR $1,042 $600 Not Implemented
ND0162 # 08 Y:1993 08 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $84 $120 Not Implemented
KU0413 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $975 $11,826 Not Implemented
KU0413 # 02 Y:1993 02 1993 ADD AREA LIGHTING SWITCHES $1,193 $3,969 Not Implemented
KU0413 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,240 $429 Implemented
KU0413 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $682 $113 Implemented
KU0413 # 05 Y:1993 05 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $293 $200 Implemented
AM0191 # 01 Y:1993 01 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,900 $2,300 Implemented
AM0191 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,800 $3,200 Implemented
AM0191 # 03 Y:1993 03 1993 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $10,200 $4,100 Implemented
AM0191 # 04 Y:1993 04 1993 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $8,650 $3,680 Not Implemented
AM0191 # 05 Y:1993 05 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $750 $0 Implemented
AM0191 # 06 Y:1993 06 1993 PAY UTILITY BILLS ON TIME $700 $0 Implemented
AM0191 # 07 Y:1993 07 1993 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $570 $0 Implemented
WV0014 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $417 $762 Implemented
WV0014 # 02 Y:1993 02 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $225 $4,980 Implemented
WV0014 # 03 Y:1993 03 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $84 $35 Not Implemented
WV0014 # 04 Y:1993 04 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,445 $2,200 Implemented
WV0014 # 05 Y:1993 05 1993 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,814 $1,840 Not Implemented
WV0014 # 06 Y:1993 06 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $90,331 $5,000 Implemented